义齿清洁剂对热聚合丙烯酸树脂物理性能的影响。

Effect of denture cleansers on physical properties of heat-polymerized acrylic resin.

机构信息

Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil.

出版信息

J Prosthodont Res. 2010 Apr;54(2):78-83. doi: 10.1016/j.jpor.2009.11.004. Epub 2010 Jan 18.

Abstract

PURPOSE

This study aimed to measure the color change, surface roughness and flexural strength of heat-polymerized acrylic resin after its immersion in denture cleansers, simulating a 180-day use.

METHODS

Thirty disk-shaped (15mm x 4mm) and 30 rectangular samples (65mm x 10mm x 3.3mm) were prepared from heat-polymerized acrylic resin and immersed in Corega Tabs, Bony Plus, and distilled water. Color measurements (DeltaE) were determined by a portable colorimeter. A surface analyzer was used to measure the roughness before and after immersion (DeltaRa). The flexural strength (S) was measured using a 3-point bending test. The DeltaE values were submitted to statistical analysis by the Kruskal-Wallis test, followed by Dunn's Multiple Comparisons test. The DeltaRa and S values were submitted to statistical analysis by ANOVA, followed by a Student-Newman-Keuls test (alpha=.05).

RESULTS

The color changes were significantly higher for the Corega Tabs than for the control group. The mean DeltaE values quantified by the National Bureau of Standards (NBS) were classified as Trace (0.0-0.5). The Bony Plus group had significantly higher surface roughness than the other groups. Corega Tabs and Bony Plus groups presented lower flexural strength than the control group.

CONCLUSIONS

Although the color changes after the immersion in denture cleansers were clinically insignificant, the Corega Tabs group showed higher color differences. The Bony Plus group showed significantly increased surface roughness. Both effervescent tablets Corega Tabs and Bony Plus significantly diminished the flexural strength of the acrylic resin.

摘要

目的

本研究旨在测量热聚合丙烯酸树脂在浸入假牙清洁剂中模拟使用 180 天后的颜色变化、表面粗糙度和弯曲强度。

方法

从热聚合丙烯酸树脂中制备 30 个圆盘状(15mm×4mm)和 30 个矩形样品(65mm×10mm×3.3mm),并将其浸入 Corega Tabs、Bony Plus 和蒸馏水。使用便携式色差计测量颜色变化(ΔE)。使用表面分析仪在浸泡前后测量粗糙度(ΔRa)。使用三点弯曲试验测量弯曲强度(S)。将 ΔE 值提交 Kruskal-Wallis 检验进行统计分析,然后进行 Dunn 多重比较检验。将 ΔRa 和 S 值提交 ANOVA 进行统计分析,然后进行 Student-Newman-Keuls 检验(α=0.05)。

结果

Corega Tabs 组的颜色变化明显高于对照组。由国家标准局(NBS)量化的平均 ΔE 值被归类为痕量(0.0-0.5)。Bony Plus 组的表面粗糙度明显高于其他组。Corega Tabs 和 Bony Plus 组的弯曲强度明显低于对照组。

结论

尽管假牙清洁剂浸泡后的颜色变化在临床意义上不明显,但 Corega Tabs 组显示出更高的颜色差异。Bony Plus 组显示出明显增加的表面粗糙度。Corega Tabs 和 Bony Plus 两种泡腾片均显著降低了丙烯酸树脂的弯曲强度。