Department of Chemistry, College of Science, Shahid Chamran University, Ahvaz, Iran.
J Hazard Mater. 2010 May 15;177(1-3):1077-84. doi: 10.1016/j.jhazmat.2010.01.031. Epub 2010 Jan 11.
A carbon paste electrode is modified with ZrO(2)-nanoparticles and its application for square wave voltammetric (SWV) detection of methyl parathion, MP (organophosphate pesticide) is reported. The nano-ZrO(2) shows a strong affinity toward the phosphate group on methyl parathion molecules, which provides sensitivity and selectivity of the modified carbon paste electrode. Instrumental and chemical parameters influencing the voltammetric response are optimized for MP determination. Under optimum experimental conditions the peak current is linear to MP concentration over the range of 5.0-3000.0 ng mL(-1) with a correlation coefficient of 0.9992. The limit of detection (LOD) and limit of quantification (LOQ) for MP based on three and ten times the standard deviation of the blank (3S(b), 10S(b)) were 2.0 and 5.7 ng mL(-1) (n=20) for MP, respectively. The recovery values from quality control (QC) samples of water solutions containing low, middle and high concentrations of MP (50, 100 and 800 ng mL(-1)) were 98.0+/-2.3%, 92.5+/-4.9% and 97.6+/-2.8%, respectively. The electrode is successfully applied for the determination of MP in different water samples.
采用纳米 ZrO2 修饰碳糊电极,并将其应用于甲基对硫磷(有机磷农药)的方波伏安(SWV)检测。纳米 ZrO2 对甲基对硫磷分子上的磷酸基团具有很强的亲和力,这为修饰碳糊电极提供了灵敏度和选择性。仪器和化学参数对 MP 测定的伏安响应进行了优化。在最佳实验条件下,峰电流在 5.0-3000.0ng mL(-1)范围内与 MP 浓度呈线性关系,相关系数为 0.9992。基于空白 3 倍和 10 倍标准偏差(3S(b)、10S(b))的甲基对硫磷检测限(LOD)和定量限(LOQ)分别为 2.0 和 5.7ng mL(-1)(n=20)。在含有低、中、高浓度 MP(50、100 和 800ng mL(-1))的水溶液中进行 QC 样品的回收值分别为 98.0+/-2.3%、92.5+/-4.9%和 97.6+/-2.8%。该电极成功应用于不同水样中 MP 的测定。