Associate Professor, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA 98195-7456, USA.
J Prosthet Dent. 2010 Jan;103(1):23-30. doi: 10.1016/S0022-3913(09)60210-9.
A new elastomeric impression material has been formulated with a ring-opening metathesis chemistry. In addition to other properties of clinical significance, the impression accuracy must be confirmed.
The purpose of this study was to compare the accuracy of the new elastomeric impression material with vinyl polysiloxane and polyether following both spray and immersion disinfection.
Impressions of a modified dentoform with a stainless steel crown preparation in the lower right quadrant were made, and type IV gypsum working casts and dies were formed. Anteroposterior (AP), cross-arch (CA), buccolingual (BL), mesiodistal (MD), occlusogingivobuccal (OGB), and occlusogingivolingual (OGL) dimensions were measured using a microscope. Working cast and die dimensions were compared to those of the master model. The impression materials were a newly formulated, ring-opening metathesis-polymerization impression material (ROMP Cartridge Tray and ROMP Volume Wash), vinyl polysiloxane (VPS, Aquasil Ultra Monophase/LV), and a polyether (PE, Impregum Penta Soft/Permadyne Garant L). Fifteen impressions with each material were made, of which 5 were disinfected by spray for 10 minutes (CaviCide), 5 were disinfected by immersion for 90 minutes (ProCide D), and 5 were not disinfected. There were significant cross-product interactions with a 2-way ANOVA, so a 1-way ANOVA and Dunnett's T3 multiple comparison test were used to compare the dimensional changes of the 3 impression materials, by disinfection status and for each location (alpha=.05).
For ROMP, there were no significant differences from the master, for any dimension, when comparing the control and 2 disinfectant conditions. No significant differences were detected among the 3 impression materials for CA, BL, and MD. The working die dimensions of OGB and OGL for VPS with immersion disinfection were significantly shorter than with PE and ROMP (P<.05). Overall, the AP dimension was more accurate than CA, and the BL of working dies was 0.040 mm greater in diameter than MD.
The accuracy of gypsum working casts and working dies from the new and 2 existing types of impression material were similar, for both spray and immersion disinfection. Judicious application of a die spacer can compensate for the small differences observed. VPS may require additional laboratory accommodation to compensate for a shorter working die.
一种新型的弹性体印模材料已通过开环复分解化学方法进行配方。除了具有临床意义的其他性能外,印模精度也必须得到确认。
本研究的目的是比较新型弹性体印模材料与乙烯基聚硅氧烷和聚醚在喷雾和浸泡消毒后的准确性。
在下颌右象限用不锈钢冠预备体制作改良牙托的印模,形成 IV 类石膏工作模型和阴模。使用显微镜测量前-后(AP)、跨弓(CA)、颊-舌(BL)、近-远中(MD)、牙合龈颊(OGB)和牙合龈舌(OGL)尺寸。工作模型和阴模的尺寸与主模型进行比较。印模材料为新配方的开环复分解聚合印模材料(ROMP Cartridge Tray 和 ROMP Volume Wash)、乙烯基聚硅氧烷(VPS,Aquasil Ultra Monophase/LV)和聚醚(PE,Impregum Penta Soft/Permadyne Garant L)。每种材料制作 15 个印模,其中 5 个用喷雾消毒 10 分钟(CaviCide),5 个用浸泡消毒 90 分钟(ProCide D),5 个不消毒。2 因素方差分析显示存在显著的交叉乘积交互作用,因此使用单因素方差分析和 Dunnett's T3 多重比较检验来比较 3 种印模材料的尺寸变化,按消毒状态和每个位置进行比较(α=.05)。
对于 ROMP,与对照和 2 种消毒条件相比,在任何尺寸上,与主模型相比均无显著差异。3 种印模材料在 CA、BL 和 MD 方面无显著差异。VPS 浸泡消毒的 OGB 和 OGL 工作阴模尺寸明显短于 PE 和 ROMP(P<.05)。总体而言,AP 尺寸比 CA 更准确,BL 直径比 MD 大 0.040mm。
新型和 2 种现有类型的印模材料制作的石膏工作模型和工作阴模的准确性相似,喷雾和浸泡消毒均可。明智地应用模具间隔器可以补偿观察到的微小差异。VPS 可能需要额外的实验室调整来补偿较短的工作模具。