Suppr超能文献

静态压力下的人体鼓膜变形

Human tympanic membrane deformation under static pressure.

作者信息

Dirckx J J, Decraemer W F

机构信息

Laboratory of Biomedical Physics, University of Antwerp, Belgium.

出版信息

Hear Res. 1991 Jan;51(1):93-105. doi: 10.1016/0378-5955(91)90009-x.

Abstract

The effect of static pressures in the range of plus and minus 1.6 kPa on the shape of tympanic membrane is measured using a non-contacting optical technique on a fresh human temporal bone. Full field data of the deformation are presented as well as cross-sections along two major directions. Strong asymmetry between medial and lateral movements is demonstrated. The displacement of the umbo is compared to other work. The rotation angle of the manubrium in function of pressure is calculated and also compared to other work. It is demonstrated that the rotation angels can not account for the measured movement of the umbo, which leads to the conclusion that for static high pressure levels the classical hypothesis of rotation around a fixed axis has to be abandoned. The comparison with data of TM displacement under dynamic stimuli is discussed.

摘要

利用非接触光学技术在新鲜的人类颞骨上测量了正负1.6 kPa范围内的静压对鼓膜形状的影响。给出了变形的全场数据以及沿两个主要方向的横截面。结果表明,鼓膜内外侧运动存在强烈不对称性。将鼓膜脐部的位移与其他研究结果进行了比较。计算了锤骨柄旋转角度随压力的变化,并与其他研究进行了比较。结果表明,旋转角度无法解释所测得的鼓膜脐部运动,由此得出结论,对于静态高压水平,必须摒弃围绕固定轴旋转的经典假设。文中还讨论了与动态刺激下鼓膜位移数据的比较。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验