Suppr超能文献

自动慢眼动(SEM)检测阻塞性睡眠呼吸暂停综合征(OSAS)患者睡眠起始:多次睡眠潜伏期试验(MSLT)与觉醒维持试验(MWT)的比较。

Automatic slow eye movement (SEM) detection of sleep onset in patients with obstructive sleep apnea syndrome (OSAS): comparison between multiple sleep latency test (MSLT) and maintenance of wakefulness test (MWT).

机构信息

Department of Neurological Sciences, University of Bologna, Via Ugo Foscolo 7, 40132 Bologna, Italy.

出版信息

Sleep Med. 2010 Mar;11(3):253-7. doi: 10.1016/j.sleep.2009.05.020. Epub 2010 Feb 16.

Abstract

OBJECTIVE

To determine whether automatic slow eye movement (SEM) analysis performs comparably to standard sleep onset criteria at the multiple sleep latency test (MSLT) and at the maintenance of wakefulness test (MWT) in patients with obstructive sleep apnea syndrome (OSAS).

METHODS

We compared sleep latencies obtained upon standard analysis of MSLT and MWT recordings with automatically detected SEM latencies in a population of 20 severe OSAS patients that randomly underwent the two tests 1 week apart.

RESULTS

Eight of 20 OSAS patients had EDS as answered by the Epworth Sleepiness Scale (ESS). Mean SEM latency performed comparably to standard sleep onset in both the MSLT (6.4+/-5.5 min versus 7.4+/-5.1 min, p=0.25) and the MWT (25.2+/-14.5 min versus 24.4+/-14.0 min, p=0.45) settings. Mean SEM latency significantly correlated with the sleep latency at the MSLT (r=0.52, p<0.05) and at the MWT (r=0.74, p<0.001). Finally, the Epworth Sleepiness Scale score correlated with SEM latency at the MWT (r=-0.62, p<0.01), but not at the MSLT.

CONCLUSIONS

Automatic SEM detection performed comparably to standard polysomnographic assessment of sleep onset, thus providing a simplified technical requirement for the MSLT and the MWT. Further studies are warranted to evaluate SEM detection of sleep onset in other sleep disorders with excessive daytime sleepiness.

摘要

目的

在阻塞性睡眠呼吸暂停综合征(OSAS)患者中,比较自动缓慢眼动(SEM)分析与多睡眠潜伏期试验(MSLT)和维持清醒试验(MWT)的标准睡眠起始标准的性能。

方法

我们比较了 20 例严重 OSAS 患者的 MSLT 和 MWT 记录的标准分析获得的睡眠潜伏期与 SEM 潜伏期的自动检测结果。这些患者随机在一周内接受了这两种测试。

结果

20 例 OSAS 患者中有 8 例根据嗜睡量表(Epworth Sleepiness Scale,ESS)回答有 EDS。在 MSLT(6.4±5.5 分钟与 7.4±5.1 分钟,p=0.25)和 MWT(25.2±14.5 分钟与 24.4±14.0 分钟,p=0.45)设置中,平均 SEM 潜伏期与标准睡眠起始值相当。平均 SEM 潜伏期与 MSLT(r=0.52,p<0.05)和 MWT(r=0.74,p<0.001)的睡眠潜伏期显著相关。最后,嗜睡量表评分与 MWT 上的 SEM 潜伏期相关(r=-0.62,p<0.01),但与 MSLT 无关。

结论

自动 SEM 检测与标准多导睡眠图评估睡眠起始相当,从而为 MSLT 和 MWT 提供了简化的技术要求。需要进一步的研究来评估 SEM 检测在其他伴有日间过度嗜睡的睡眠障碍中的睡眠起始。