Suppr超能文献

视网膜病专家对早产儿视网膜病变诊断的准确性。

Accuracy of retinopathy of prematurity diagnosis by retinal fellows.

机构信息

Department of Ophthalmology, Weill Cornell Medical College, New York, New York, USA.

出版信息

Retina. 2010 Jun;30(6):958-65. doi: 10.1097/IAE.0b013e3181c9696a.

Abstract

PURPOSE

The purpose of this study was to measure the accuracy of retinopathy of prematurity (ROP) diagnosis by retinal fellows.

METHODS

An atlas of 804 retinal images was captured from 248 eyes of 67 premature infants with a wide-angle camera (RetCam-II, Clarity Medical Systems, Pleasanton, CA). Images were uploaded to a study Web site, from which an expert pediatric retinal specialist and 7 retinal fellows independently provided a diagnosis (no ROP, mild ROP, type 2 ROP, or treatment-requiring ROP) for each eye. The sensitivity and specificity of each retinal fellow were calculated and subsequently compared with a reference standard of diagnosis by an expert pediatric retinal specialist.

RESULTS

For detection of type 2 or worse ROP by fellows, mean (range) sensitivity was 0.751 (0.512-0.953), and specificity was 0.841 (0.707-0.976). For detection of treatment-requiring ROP, mean (range) sensitivity was 0.914 (0.667-1.000), and specificity was 0.871 (0.678-0.987).

CONCLUSION

In general, fellows showed high accuracy for detecting ROP. However, 3 of 7 fellows achieved <80% sensitivity for diagnosis of type 2 or worse ROP, and 2 of 7 achieved <90% sensitivity for diagnosis of treatment-requiring ROP. This could lead to undermanagement and undertreatment of clinically significant disease and raises potential concerns about the quality of ROP screening examinations performed by less-experienced examiners.

摘要

目的

本研究旨在评估视网膜住院医师对早产儿视网膜病变(ROP)的诊断准确性。

方法

使用广角相机(RetCam-II,Clarity Medical Systems,Pleasanton,CA)从 67 名早产儿的 248 只眼中捕获了 804 张视网膜图像。将图像上传到研究网站,由一名专家儿科视网膜专家和 7 名视网膜住院医师独立对每只眼进行诊断(无 ROP、轻度 ROP、2 型 ROP 或需要治疗的 ROP)。计算每位视网膜住院医师的敏感性和特异性,并随后与专家儿科视网膜专家的诊断参考标准进行比较。

结果

对于 2 型或更严重 ROP 的检测,住院医师的平均(范围)敏感性为 0.751(0.512-0.953),特异性为 0.841(0.707-0.976)。对于治疗性 ROP 的检测,住院医师的平均(范围)敏感性为 0.914(0.667-1.000),特异性为 0.871(0.678-0.987)。

结论

总体而言,住院医师对 ROP 的检测具有较高的准确性。然而,7 名住院医师中有 3 名的 2 型或更严重 ROP 诊断敏感性低于 80%,2 名的治疗性 ROP 诊断敏感性低于 90%。这可能导致对临床显著疾病的管理和治疗不足,并对经验不足的检查者进行的 ROP 筛查检查的质量提出潜在担忧。

相似文献

4
Diagnostic Discrepancies in Retinopathy of Prematurity Classification.早产儿视网膜病变分类中的诊断差异。
Ophthalmology. 2016 Aug;123(8):1795-1801. doi: 10.1016/j.ophtha.2016.04.035. Epub 2016 May 27.

引用本文的文献

7
Telemedical Diagnosis of Stage 4 and Stage 5 Retinopathy of Prematurity.早产儿视网膜病变4期和5期的远程医疗诊断
Ophthalmol Retina. 2018 Jan;2(1):59-64. doi: 10.1016/j.oret.2017.04.001. Epub 2017 Jun 9.

本文引用的文献

1
Retinopathy of prematurity malpractice claims.早产儿视网膜病变医疗事故索赔。
Arch Ophthalmol. 2009 Jun;127(6):803-4. doi: 10.1001/archophthalmol.2009.117.
5
Births: final data for 2005.出生情况:2005年最终数据。
Natl Vital Stat Rep. 2007 Dec 5;56(6):1-103.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验