Suppr超能文献

伪连续动脉自旋标记的标记效率估计。

Estimation of labeling efficiency in pseudocontinuous arterial spin labeling.

机构信息

Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas 75390, USA.

出版信息

Magn Reson Med. 2010 Mar;63(3):765-71. doi: 10.1002/mrm.22245.

Abstract

Pseudocontinuous arterial spin labeling MRI is a new arterial spin labeling technique that has the potential of combining advantages of continuous arterial spin labeling and pulsed arterial spin labeling. However, unlike continuous arterial spin labeling, the labeling process of pseudocontinuous arterial spin labeling is not strictly an adiabatic inversion and the efficiency of labeling may be subject specific. Here, three experiments were performed to study the labeling efficiency in pseudocontinuous arterial spin labeling MRI. First, the optimal labeling position was determined empirically to be approximately 84 mm below the anterior commissure-posterior commissure line in order to achieve the highest sensitivity. Second, an experimental method was developed to utilize phase-contrast velocity MRI as a normalization factor and to estimate the labeling efficiency in vivo, which was founded to be 0.86 +/- 0.06 (n = 10, mean +/- standard deviation). Third, we compared the labeling efficiency of pseudocontinuous arterial spin labeling MRI under normocapnic and hypercapnic (inhalation of 5% CO(2)) conditions and showed that a higher flow velocity in the feeding arteries resulted in a reduction in the labeling efficiency. In summary, our results suggest that labeling efficiency is a critical parameter in pseudocontinuous arterial spin labeling MRI not only in terms of achieving highest sensitivity but also in quantification of absolute cerebral blood flow in milliliters per minute per 100 g. We propose that the labeling efficiency should be estimated using phase-contrast velocity MRI on a subject-specific basis.

摘要

伪连续动脉自旋标记 MRI 是一种新的动脉自旋标记技术,它有可能结合连续动脉自旋标记和脉冲动脉自旋标记的优点。然而,与连续动脉自旋标记不同,伪连续动脉自旋标记的标记过程不是严格的绝热反转,并且标记效率可能是个体特异性的。在这里,进行了三项实验来研究伪连续动脉自旋标记 MRI 中的标记效率。首先,通过经验确定最佳标记位置大约在前连合-后连合线以下 84mm,以获得最高的灵敏度。其次,开发了一种实验方法,利用相位对比速度 MRI 作为归一化因子,在体内估计标记效率,结果发现为 0.86 +/- 0.06(n=10,平均值 +/- 标准差)。第三,我们比较了在正常碳酸血症和高碳酸血症(吸入 5%CO2)条件下伪连续动脉自旋标记 MRI 的标记效率,结果表明,给动脉中的流速较高会导致标记效率降低。总之,我们的结果表明,标记效率是伪连续动脉自旋标记 MRI 中的一个关键参数,不仅在实现最高灵敏度方面,而且在量化每分钟每 100 克的绝对脑血流量方面也是如此。我们建议根据个体情况使用相位对比速度 MRI 来估计标记效率。

相似文献

1
Estimation of labeling efficiency in pseudocontinuous arterial spin labeling.
Magn Reson Med. 2010 Mar;63(3):765-71. doi: 10.1002/mrm.22245.
3
Arterial cerebral blood volume-weighted functional MRI using pseudocontinuous arterial spin tagging (AVAST).
Magn Reson Med. 2015 Mar;73(3):1053-64. doi: 10.1002/mrm.25220. Epub 2014 Apr 18.
4
Determination of spin compartment in arterial spin labeling MRI.
Magn Reson Med. 2011 Jan;65(1):120-7. doi: 10.1002/mrm.22601.
5
Robust method for 3D arterial spin labeling in mice.
Magn Reson Med. 2012 Jul;68(1):98-106. doi: 10.1002/mrm.23209. Epub 2011 Nov 18.
7
Cerebral blood flow quantification in swine using pseudo-continuous arterial spin labeling.
J Magn Reson Imaging. 2013 Nov;38(5):1111-8. doi: 10.1002/jmri.24066. Epub 2013 Sep 16.
8
An introduction to ASL labeling techniques.
J Magn Reson Imaging. 2014 Jul;40(1):1-10. doi: 10.1002/jmri.24565. Epub 2014 Jan 15.
9
Superselective pseudocontinuous arterial spin labeling.
Magn Reson Med. 2010 Sep;64(3):777-86. doi: 10.1002/mrm.22451.
10
Measuring the labeling efficiency of pseudocontinuous arterial spin labeling.
Magn Reson Med. 2017 May;77(5):1841-1852. doi: 10.1002/mrm.26266. Epub 2016 May 13.

引用本文的文献

1
Problems and solutions in quantifying cerebrovascular reactivity using BOLD-MRI.
Imaging Neurosci (Camb). 2025 May 2;3. doi: 10.1162/imag_a_00556. eCollection 2025.
2
Phase contrast-derived cerebral blood flow is associated with neurodegeneration and cerebrovascular injury in older adults.
Front Neurosci. 2025 Jul 4;19:1538956. doi: 10.3389/fnins.2025.1538956. eCollection 2025.
3
SNR-efficient whole-brain pseudo-continuous arterial spin labeling perfusion imaging at 7 T.
Magn Reson Med. 2025 Sep;94(3):965-981. doi: 10.1002/mrm.30527. Epub 2025 May 28.
4
Variable cerebral blood flow responsiveness to acute hypoxic hypoxia.
Front Physiol. 2025 Mar 12;16:1562582. doi: 10.3389/fphys.2025.1562582. eCollection 2025.
5
Acute psilocybin and ketanserin effects on cerebral blood flow: 5-HT2AR neuromodulation in healthy humans.
J Cereb Blood Flow Metab. 2025 Feb 26:271678X251323364. doi: 10.1177/0271678X251323364.
6
Variable Cerebral Blood Flow Responsiveness to Acute Hypoxic Hypoxia.
bioRxiv. 2024 Nov 15:2024.11.14.623430. doi: 10.1101/2024.11.14.623430.

本文引用的文献

2
Minimizing acquisition time of arterial spin labeling at 3T.
Magn Reson Med. 2008 Jun;59(6):1467-71. doi: 10.1002/mrm.21633.
4
Vessel-encoded arterial spin-labeling using pseudocontinuous tagging.
Magn Reson Med. 2007 Dec;58(6):1086-91. doi: 10.1002/mrm.21293.
6
Model-free arterial spin labeling quantification approach for perfusion MRI.
Magn Reson Med. 2006 Feb;55(2):219-32. doi: 10.1002/mrm.20784.
7
Single-shot 3D imaging techniques improve arterial spin labeling perfusion measurements.
Magn Reson Med. 2005 Aug;54(2):491-8. doi: 10.1002/mrm.20580.
8
Routine clinical brain MRI sequences for use at 3.0 Tesla.
J Magn Reson Imaging. 2005 Jul;22(1):13-22. doi: 10.1002/jmri.20356.
10
Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study.
Radiology. 2005 Apr;235(1):218-28. doi: 10.1148/radiol.2351031663. Epub 2005 Feb 16.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验