Suppr超能文献

口服造影剂配方的流动特性取决于温度。

Flow properties of oral contrast medium formulations depend on the temperature.

作者信息

Ekberg Olle, Stading Mats, Johansson Daniel, Bülow Margareta, Ekman Susanne, Wendin Karin

机构信息

Department of Clinical Sciences/Medical Radiology, Lund University, Lund, Sweden.

出版信息

Acta Radiol. 2010 May;51(4):363-7. doi: 10.3109/02841851003645751.

Abstract

BACKGROUND

During the therapeutic videofluoroscopic examination of swallowing, gradation of bolus volume, texture, and viscosity can be implemented to determine the optimal bolus characteristics in that particular patient. When a thickened liquid is given to a dysphagic patient it is served at room temperature. However, in these patients with a delayed oral and/or pharyngeal stage of swallow, the bolus is held for a long time in the oral cavity. The temperature of the thickened liquid thereby increases.

PURPOSE

To study the rheological exploration (variation of viscosity with temperature) of thickened food used for radiologic swallowing examinations in patients with oral and pharyngeal dysfunction, in particular in mixtures of barium sulfate suspensions and in iodine solutions.

MATERIAL AND METHODS

Deep-frozen mango purée was thawed at room temperature. It was then mixed with barium sulfate contrast medium to a density of 25% w/w. Resorce Thicken Up was mixed at room temperature at two concentrations: 4.3% w/w (4.5 g thickener + 100 g distilled water) and 6.0% w/w (4.5 g thickener + 70 g distilled water). The thickener consisted of modified corn starch. Resorce Thicken Up was also mixed at room temperature with two concentrations of an iodine contrast material, iohexol (Omnipaque, 350 mg I/ml). The two concentrations were: 4.3% w/w (4.5 g thickener + 100 g iohexol) and 6% w/w (6 g thickener + 100 g iohexol). Measurements were carried out from 20 degrees C to 37 degrees C using a Stresstech HR rheometer. The rheometer was equipped with a concentric cylinder measuring system (inner cylinder 15 mm).

RESULTS

The samples containing thickener in water as well as in iohexol showed a dependence on thickener concentration and temperature. The mango purée with barium sulfate displayed very small temperature dependence. The thickener solutions in iohexol had significantly higher viscosity compared with the other thickener solutions and the mango purée. The relative decrease shows that mango purée, the 6% thickener solution in water, and solutions with iohexol exhibited similar relative viscosity change at different temperatures.

CONCLUSION

Our conclusion is therefore that it is important always to make the solution with high precision. It is also of importance to observe how long the patient keeps the bolus in the mouth. This might vary and actually it may not be possible to influence this factor. When different types of thickeners are compared, it is important to take into account the temperature at which the thickener is observed.

摘要

背景

在吞咽治疗性视频荧光检查期间,可以对食团体积、质地和黏度进行分级,以确定特定患者的最佳食团特征。给吞咽困难的患者提供增稠液体时,液体的温度为室温。然而,对于口腔和/或咽部吞咽阶段延迟的患者,食团会在口腔中停留很长时间。增稠液体的温度因此会升高。

目的

研究用于口腔和咽部功能障碍患者放射学吞咽检查的增稠食物的流变学特性(黏度随温度的变化),特别是硫酸钡混悬液混合物和碘溶液的流变学特性。

材料与方法

将深度冷冻的芒果泥在室温下解冻。然后将其与硫酸钡造影剂混合,使其密度达到25%(重量/重量)。在室温下将增稠剂Resorce Thicken Up按两种浓度混合:4.3%(重量/重量)(4.5克增稠剂+100克蒸馏水)和6.0%(重量/重量)(4.5克增稠剂+70克蒸馏水)。增稠剂由改性玉米淀粉组成。还在室温下将增稠剂Resorce Thicken Up与两种浓度的碘造影剂碘海醇(欧乃派克,350毫克碘/毫升)混合。两种浓度分别为:4.3%(重量/重量)(4.5克增稠剂+100克碘海醇)和6%(重量/重量)(6克增稠剂+100克碘海醇)。使用Stresstech HR流变仪在20摄氏度至37摄氏度之间进行测量。流变仪配备同心圆柱测量系统(内圆柱直径15毫米)。

结果

在水中以及在碘海醇中含有增稠剂的样品表现出对增稠剂浓度和温度的依赖性。含有硫酸钡的芒果泥对温度的依赖性非常小。与其他增稠剂溶液和芒果泥相比,碘海醇中的增稠剂溶液具有显著更高的黏度。相对降低表明,芒果泥、6%的水中增稠剂溶液以及含碘海醇的溶液在不同温度下表现出相似的相对黏度变化。

结论

因此,我们的结论是,始终高精度地配制溶液很重要。观察患者将食团留在口中的时间也很重要。这个时间可能会有所不同,实际上可能无法影响这个因素。比较不同类型的增稠剂时,考虑观察增稠剂时的温度很重要。