Reliable jitter and shimmer measurements in voice clinics: the relevance of vowel, gender, vocal intensity, and fundamental frequency effects in a typical clinical task.

机构信息

Speech Pathology Section, Department of Phoniatry and Speech Pathology, Clinic for Otorhinolaryngology, Head and Neck Surgery, University Hospital Zurich, Zurich, Switzerland.

出版信息

J Voice. 2011 Jan;25(1):44-53. doi: 10.1016/j.jvoice.2009.07.002. Epub 2010 Apr 8.

Abstract

The aims of this study were to examine vowel and gender effects on jitter and shimmer in a typical clinical voice task while correcting for the confounding effects of voice sound pressure level (SPL) and fundamental frequency (F(0)). Furthermore the relative effect sizes of vowel, gender, voice SPL, and F(0) were assessed, and recommendations for clinical measurements were derived. With this cross-sectional single cohort study, 57 healthy adults (28 women, 29 men) aged 20-40 years were investigated. Three phonations of /a/, /o/, and /i/ at "normal" voice loudness were analyzed using Praat (software). The effects of vowel, gender, voice SPL, and F(0) on jitter and shimmer were assessed using descriptive and inferential (analysis of covariance) statistics. The effect sizes were determined with the eta-squared statistic. Vowels, gender, voice SPL, and F(0), each had significant effects either on jitter or on shimmer, or both. Voice SPL was the most important factor, whereas vowel, gender, and F(0) effects were comparatively small. Because men had systematically higher voice SPL, the gender effects on jitter and shimmer were smaller when correcting for SPL and F(0). Surprisingly, in clinical assessments, voice SPL has the single biggest impact on jitter and shimmer. Vowel and gender effects were clinically important, whereas fundamental frequency had a relatively small influence. Phonations at a predefined voice SPL (80 dB minimum) and vowel (/a/) would enhance measurement reliability. Furthermore, gender-specific thresholds applying these guidelines should be established. However, the efficiency of these measures should be verified and tested with patients.

摘要

本研究旨在考察在纠正嗓音声压级(SPL)和基频(F0)混杂效应的情况下,元音和性别对颤音和齿音的影响。此外,还评估了元音、性别、嗓音 SPL 和 F0 的相对效应大小,并得出了临床测量的建议。本研究采用横断面单队列研究,共纳入 57 名年龄在 20-40 岁的健康成年人(28 名女性,29 名男性)。使用 Praat(软件)分析了三个音:/a/、/o/和/i/,在“正常”嗓音响度下进行发音。使用描述性和推论性(协方差分析)统计方法评估了元音、性别、嗓音 SPL 和 F0 对颤音和齿音的影响。使用 eta-squared 统计量确定效应大小。元音、性别、嗓音 SPL 和 F0 对颤音和齿音均有显著影响,或对其中之一有影响,或两者均有影响。嗓音 SPL 是最重要的因素,而元音、性别和 F0 的影响相对较小。由于男性的嗓音 SPL 普遍较高,因此在纠正 SPL 和 F0 后,性别对颤音和齿音的影响较小。令人惊讶的是,在临床评估中,嗓音 SPL 对颤音和齿音的影响最大。元音和性别效应具有临床重要性,而基频的影响相对较小。在预设嗓音 SPL(最小 80dB)和元音(/a/)下进行发音将提高测量的可靠性。此外,应针对这些指南建立特定性别的阈值。然而,这些措施的效率需要通过患者进行验证和测试。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验