A novel technique for the semi-automated measurement of embryo volume: an intraobserver reliability study.

机构信息

Nottingham University Research & Treatment Unit in Reproduction (NURTURE), Nottingham University Hospitals NHS Trust, Nottingham, UK.

出版信息

Ultrasound Med Biol. 2010 May;36(5):719-25. doi: 10.1016/j.ultrasmedbio.2010.03.006. Epub 2010 Apr 9.

Abstract

The aim was to assess intraobserver reliability of a new semi-automated technique of embryo volumetry. Power calculations suggested 46 subjects with viable, singleton pregnancies were required for reliability analysis. Crown rump length (CRL) of each embryo was analyzed using 2-D and a 3-D dataset acquired using transvaginal ultrasound. Virtual organ computer-aided analysis (VOCAL) was used to calculate volume of gestation sac (GSV) and yolk sac (YSV) and SonoAVC (sonography-based automated volume count) was used to quantify fluid volume (FV). Embryo volume was calculated by subtracting FV and YSV from GSV. Each dataset was measured twice. Reliability was assessed using Bland-Altman plots and intraclass correlation coefficients (ICCs). Fifty-two datasets were analyzed. Median embryo volume was 1.8 cm(3) (0.1 to 8.1 cm(3)); median gestational age 7 + 4 weeks; median CRL 13 mm (2 to 29 mm). Mean difference of embryo volume measurements was 0.1cm(3) (limits of agreement [LOA] -0.3 to 0.4 cm(3)); multiples of mean (MoM) 0.38; mean difference of CRL measurements 0.3 mm (LOA -1.4 to 2.0 mm), MoM = 0.26. ICC for embryo volume was 0.999 (95%CI 0.998 to 0.999), confirming excellent intraobserver agreement. ICC for CRL was 0.996 (95%CI 0.991 to 0.998). Regression analysis showed good correlation between embryo volume and CRL (R(2) = 0.60). The new semi-automated 3-D technique provides reliable measures of embryo volume. Further work is required to assess the validity of this technique.

摘要

目的是评估一种新的半自动胚胎体积测量技术的观察者内可靠性。根据功效计算,需要 46 例具有活胎、单胎妊娠的患者进行可靠性分析。使用经阴道超声获得的二维和三维数据集分析每个胚胎的头臀长(CRL)。使用虚拟器官计算机辅助分析(VOCAL)计算孕囊(GSV)和卵黄囊(YSV)的体积,使用 SonoAVC(基于超声的自动体积计数)量化羊水体积(FV)。胚胎体积通过从 GSV 中减去 FV 和 YSV 来计算。每个数据集测量两次。使用 Bland-Altman 图和组内相关系数(ICC)评估可靠性。分析了 52 个数据集。胚胎体积中位数为 1.8cm³(0.1 至 8.1cm³);妊娠年龄中位数为 7+4 周;CRL 中位数为 13mm(2 至 29mm)。胚胎体积测量的平均差值为 0.1cm³(95%置信区间[LOA]为-0.3 至 0.4cm³);倍数均值(MoM)为 0.38;CRL 测量的平均差值为 0.3mm(LOA 为-1.4 至 2.0mm),MoM=0.26。胚胎体积的 ICC 为 0.999(95%置信区间 0.998 至 0.999),证实了观察者内的高度一致性。CRL 的 ICC 为 0.996(95%置信区间 0.991 至 0.998)。回归分析显示胚胎体积与 CRL 之间存在良好的相关性(R²=0.60)。新的半自动 3D 技术可提供可靠的胚胎体积测量值。需要进一步研究来评估该技术的有效性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验