Suppr超能文献

弹性蛋白酶诱导的小鼠腹主动脉瘤评估:超声成像与原位视频显微镜检查的比较。

Assessment of elastase-induced murine abdominal aortic aneurysms: comparison of ultrasound imaging with in situ video microscopy.

作者信息

Azuma Junya, Maegdefessel Lars, Kitagawa Toshiro, Dalman Ronald L, McConnell Michael V, Tsao Philip S

机构信息

Division of Cardiovascular Medicine, Stanford University School of Medicine, CA, USA.

出版信息

J Biomed Biotechnol. 2011;2011:252141. doi: 10.1155/2011/252141. Epub 2011 Feb 6.

Abstract

AIMS

The aim of this study was to definitively assess the validity of noninvasive high-frequency ultrasound (US) measurements of aortic luminal diameter (ALD) in a murine model of elastase-induced abdominal aortic aneurysm in comparison with in situ video microscopy (VM).

METHODS

C57BL/6 mice underwent transient perfusion of the aorta with either elastase (n = 20: Elastase group) or saline (n = 10: Sham). Unoperated mice (n = 10) were also studied.

RESULTS

ALD measurements by US had excellent linear correlation and absolute agreement with that by VM in both Control (unoperated or sham-operated mice) and elastase groups (r = 0.96, intraclass correlation coefficient (ICC) = 0.88 and r = 0.93, ICC = 0.92, resp.). Bland-Altman analysis of US compared with VM measurements in both groups indicated good agreement, however US measurements were slightly but significantly higher than VM measurements in the control group (mean bias 0.039 mm, P < .05). Linear regression analysis revealed excellent correlation between US and VM measurements in both groups. (R² = 0.91 in Control group, R² = 0.85 in elastase group.) The reliability of US measurements was also confirmed by ex vivo histological measurements.

CONCLUSIONS

High-frequency US provides reliable ALD measurements in developing murine abdominal aortic aneurysms.

摘要

目的

本研究旨在与原位视频显微镜检查(VM)相比,最终评估在弹性蛋白酶诱导的腹主动脉瘤小鼠模型中,无创高频超声(US)测量主动脉管腔直径(ALD)的有效性。

方法

C57BL/6小鼠接受用弹性蛋白酶(n = 20:弹性蛋白酶组)或生理盐水(n = 10:假手术组)对主动脉进行短暂灌注。还对未手术的小鼠(n = 10)进行了研究。

结果

在对照组(未手术或假手术小鼠)和弹性蛋白酶组中,US测量的ALD与VM测量的ALD具有极好的线性相关性和绝对一致性(分别为r = 0.96,组内相关系数(ICC)= 0.88和r = 0.93,ICC = 0.92)。两组中US与VM测量值的Bland-Altman分析表明一致性良好,然而在对照组中US测量值略高于但显著高于VM测量值(平均偏差0.039 mm,P <.05)。线性回归分析显示两组中US和VM测量值之间具有极好的相关性。(对照组中R² = 0.91,弹性蛋白酶组中R² = 0.85。)体外组织学测量也证实了US测量的可靠性。

结论

高频US在发育中的小鼠腹主动脉瘤中提供可靠的ALD测量。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4243/3038624/6ba9e902c686/JBB2011-252141.001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验