Postle A D, Goodland F C
Ann Clin Biochem. 1978 Jan;15(1):18-24. doi: 10.1177/000456327801500103.
Two new automated methods for serum triglyceride analysis are described and compared with each other and with an established chemical method. They are a chemical method requiring no glycerol blank correction and a commercially available fully enzymatic method requiring no prior lipid extraction. Both methods had higher quality control precision and faster sampling rates than the established method. Comparison of duplicate analyses of a random series of serum samples by all three methods gave a closer correlation between the new methods than between either and the conventional method.
本文描述了两种用于血清甘油三酯分析的新型自动化方法,并将它们相互比较,同时与一种已确立的化学方法进行比较。它们一种是无需甘油空白校正的化学方法,另一种是无需预先进行脂质提取的市售全酶法。这两种方法均比已确立的方法具有更高的质量控制精度和更快的采样速率。对一系列随机血清样本进行的所有三种方法的重复分析比较表明,新方法之间的相关性比新方法与传统方法之间的相关性更强。