Automated procedure for kinetic measurement of total triglycerides (as glycerol) in serum with the Gilford System 3500.

作者信息

Lehnus G, Smith L

出版信息

Clin Chem. 1978 Jan;24(1):27-31.

PMID:618662
Abstract

An automated procedure is used on the Gilford 3500 Computer-Directed Analyzer to measure serum triglycerides indirectly by using aqueous glycerol standards. Most enzymatic methods require long hydrolysis or awkward saponification. The method of Bucolo and David [clin. Chem. 19, 476 (1973)], in which lipase and glycerol kinase are used, is modified. The kinetic procedure described eliminates the need for a serum blank. It uses "Eskalab" bulk reagents and reduces both time and cost per test by measuring the decreasing NADH concentration from the glycerol kinase reaction at 340 nm after enzymatic hydrolysis at room temperature. The change in absorbance of the standard during a 14-s measuring time is used in the ratiometric calculation of the unknowns. The use of a stable aqueous standard that can be reliably and accurately prepared makes this method ideal for the traceability desired by many organizations. Reagent blank drift did not affect the results. A correlation coefficient of 0.991 for comparison with the manual endpoint method and a typical CV of 2.25% show this method to be accurate and reliable.

摘要

相似文献

1
Automated procedure for kinetic measurement of total triglycerides (as glycerol) in serum with the Gilford System 3500.
Clin Chem. 1978 Jan;24(1):27-31.
2
Automated measurement of total cholesterol and triglycerides, in "tandem," on the discrete sample analyzer, Gilford System 3500.
Clin Chem. 1979 Mar;25(3):439-42.
3
Fluorometric estimation of triglycerides in serum by a modification of the method of Bucolo and David.
Clin Chem. 1977 Feb;23(2 PT. 1):286-8.
4
Determination of serum triglycerides by an accurate enzymatic method not affected by free glycerol.
Clin Chem. 1985 Jul;31(7):1227-8.
5
Lipase-triggered kinetic assay of serum triglycerides.
Clin Chem. 1975 Mar;21(3):424-6.
6
A semi-automated enzymatic assay for free glycerol and triglycerides in serum or plasma.一种用于检测血清或血浆中游离甘油和甘油三酯的半自动酶法测定。
Clin Biochem. 1977 Feb;10(1):16-9. doi: 10.1016/s0009-9120(77)90232-6.
7
Mechanized enzymatic determination of triglycerides in serum.
Clin Chem. 1975 Mar;21(3):420-4.
8
Enzymatic determination of triglycerides with a system Olli 3000 analyser.
Scand J Clin Lab Invest. 1978 Apr;38(2):189-92. doi: 10.3109/00365517809156088.
9
Otimum kinetic enzymatic procedures for glucose and triglycerides in plasma and serum.
Clin Chem. 1975 Sep;21(10):1448-53.
10
Simplified, totally enzymatic method for determination of serum triglycerides with a centrifugal analyzer.
Clin Chem. 1976 Aug;22(8):1310-3.

引用本文的文献

1
Increased arachidonic acid incorporation into platelet phospholipids in type 2 (non-insulin-dependent) diabetes.2型(非胰岛素依赖型)糖尿病患者血小板磷脂中花生四烯酸掺入增加。
Diabetologia. 1984 Feb;26(2):134-7. doi: 10.1007/BF00281120.