Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens University, Innrain 52a, 6020 Innsbruck, Austria.
J Mass Spectrom. 2010 May;45(5):545-52. doi: 10.1002/jms.1740.
In spite of the growing acceptance of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the analysis of a wide variety of compounds, including polymers and proteins, its use in analyzing low-molecular-weight molecules (<1000 m/z) is still limited. This is mainly due to the interference of matrix molecules in the low-mass range. Here the derivatized fullerenes covalently bound to silica particles with different pore sizes are applied as thin layer for laser desorption/ionization (LDI) mass spectrometric analysis. Thus, an interference of intrinsic matrix ions can be eliminated or minimized in comparison with the state-of-the-art weak organic acid matrices. The desorption/ionization ability of the developed fullerene-silica materials depends on the applied laser power, sample preparation and pore size of the silica particles. Thus, fullerene-silica serves as an LDI support for mass spectrometric analysis of molecules (<1500 Da). The performance of the fullerene-silica is demonstrated by the mass analysis of variety of small molecules such as carbohydrates, amino acids, peptides, phospholipids and drugs.
尽管基质辅助激光解吸/电离飞行时间质谱法(MALDI-TOF MS)在分析各种化合物(包括聚合物和蛋白质)方面的应用越来越广泛,但它在分析低分子量分子(<1000 m/z)方面的应用仍然有限。这主要是由于基质分子在低质量范围内的干扰。本文中,将不同孔径的硅球共价键合的衍生富勒烯作为薄层应用于激光解吸/电离(LDI)质谱分析。与现有的弱有机酸基质相比,这种方法可以消除或最小化固有基质离子的干扰。所开发的富勒烯-硅材料的解吸/电离能力取决于所应用的激光功率、样品制备和硅颗粒的孔径。因此,富勒烯-硅作为质谱分析分子量<1500 Da 的分子的 LDI 支持物。富勒烯-硅的性能通过对各种小分子(如碳水化合物、氨基酸、肽、磷脂和药物)的质谱分析得到了证明。