Iladevi Cataract & IOL Research Centre, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India.
J Cataract Refract Surg. 2010 May;36(5):771-7. doi: 10.1016/j.jcrs.2009.11.027.
To evaluate the anatomic location of the haptic and optic of single-piece sulcus-fixated intraocular lenses (IOLs) and their proximity to the iris and ciliary body using ultrasound biomicroscopy (UBM).
Iladevi Cataract & IOL Research Center, Ahmedabad, India.
This retrospective study comprised eyes that had primary sulcus implantation of a single-piece IOL. Eyes had an intact anterior capsulorhexis that could provide uniform IOL support and a preoperative anterior chamber depth (ACD) greater than 2.7 mm. The fixation site of the haptics, distance between the optic edge and iris, optic tilt, anterior chamber angle (ACA), central ACD, and ciliary body edema were evaluated by UBM.
The time from surgery to UBM examination was 7 to 85 months. Both haptics were in the sulcus in 7 of the 10 eyes, 1 haptic was abutting the iris and the other was in the sulcus in 2 eyes, and both haptics were embedded in ciliary body in 1 eye. The mean distance between the optic edge and iris was 0.16 mm +/- 0.07 (SD), 0.15 +/- 0.03 mm, and 0.38 mm, respectively. The mean ACA was 40.2 +/- 4.5 degrees (range 30.9 to 45.2 degrees), 34.1 +/- 4.5 degrees, and 44.1 degrees, respectively. The mean ACD was 3.47 +/- 0.24 mm, 3.50 +/- 0.23 mm, and 3.57 mm, respectively. No eye had optic tilt or ciliary body edema.
Implantation of both haptics in the sulcus was not achieved in all eyes. The haptics and optics remained in close proximity to the posterior iris surface.
使用超声生物显微镜(UBM)评估单焦点巩膜固定型人工晶状体(IOL)的襻和光学部的解剖位置及其与虹膜和睫状体的接近程度。
印度艾哈迈达巴德的 Iladevi 白内障和 IOL 研究中心。
本回顾性研究包括接受单焦点 IOL 巩膜固定术的眼。这些眼均有完整的前囊膜环形撕囊,可以为 IOL 提供均匀的支撑,术前前房深度(ACD)大于 2.7mm。使用 UBM 评估襻的固定位置、光学部边缘与虹膜的距离、光学倾斜度、前房角(ACA)、中央 ACD 和睫状体水肿。
从手术到 UBM 检查的时间为 7 至 85 个月。10 只眼中,7 只眼的两个襻均位于巩膜沟内,2 只眼的 1 个襻与虹膜接触,另 1 个襻位于巩膜沟内,1 只眼的两个襻均嵌入睫状体。光学部边缘与虹膜的平均距离分别为 0.16mm±0.07(SD)、0.15mm±0.03mm 和 0.38mm。平均 ACA 分别为 40.2°±4.5°(范围 30.9°至 45.2°)、34.1°±4.5°和 44.1°。平均 ACD 分别为 3.47mm±0.24mm、3.50mm±0.23mm 和 3.57mm。所有眼均无光学倾斜或睫状体水肿。
并非所有眼均能将两个襻完全植入巩膜沟内。襻和光学部仍与后虹膜表面接近。