Kanamori K, Shiba K, Sugiura K
Department of Clinical Biochemistry, Faculty of Medicine, Tokyo Medicine and Dental University.
Rinsho Byori. 1991 Apr;39(4):398-404.
Because standard urinary protein test paper reacts more strongly to albumin than to globulin, we attempted to develop a test paper sensitive to globulin by applying chromatic analysis principles used in quantitative analysis of urinary protein. We developed a new urinary protein test paper (URINE-TP) containing a reagent of ACID VIOLET 17. It was found that URINE-TP reacts with the same strength to gamma-globulin as to albumin. This new test paper therefore allows accurate detection of Bence Jones protein, which was formerly detectable with standard test paper. There was a correlation between values for urinary protein obtained with URINE-TP and those obtained by quantitative analysis. As with standard test paper, URINE-TP indicates urinary protein values in the normal range by a lack of reaction, but on URINE-TP positive and negative results are more clearly distinguishable than on standard test paper. From these results, we conclude that URINE-TP enables detection of both gamma-globulin and albumin in the urine, and that is as sensitive as the analytical method in the screening of urinary proteins.
由于标准尿蛋白试纸对白蛋白的反应比对球蛋白的反应更强,我们尝试通过应用尿蛋白定量分析中使用的色度分析原理来开发一种对球蛋白敏感的试纸。我们开发了一种含有酸性紫17试剂的新型尿蛋白试纸(URINE-TP)。结果发现,URINE-TP对γ球蛋白和白蛋白的反应强度相同。因此,这种新型试纸能够准确检测本-周蛋白,而本-周蛋白以前只能用标准试纸检测。URINE-TP测得的尿蛋白值与定量分析测得的值之间存在相关性。与标准试纸一样,URINE-TP通过无反应表明尿蛋白值在正常范围内,但与标准试纸相比,URINE-TP的阳性和阴性结果更易于区分。从这些结果中,我们得出结论,URINE-TP能够检测尿液中的γ球蛋白和白蛋白,并且在尿蛋白筛查中与分析方法一样敏感。