Suppr超能文献

采用高分辨率外周定量 CT 评估类风湿关节炎患者手部骨丢失。

Assessment of hand bone loss in rheumatoid arthritis by high-resolution peripheral quantitative CT.

机构信息

INSERM U831, Université de Lyon, Service de Rhumatologie, Hôpital Edouard Herriot, 5 Place d'Arsonval, Lyon, France.

出版信息

Ann Rheum Dis. 2010 Sep;69(9):1671-6. doi: 10.1136/ard.2009.114512. Epub 2010 Jun 4.

Abstract

OBJECTIVES

A new high-resolution peripheral quantitative CT (HR-pQCT) system allows for in vivo assessment of bone microarchitecture and volumetric bone mineral density (vBMD) with an 82 microm isotropic resolution. With this device, the microarchitecture impairment was evaluated in patients with rheumatoid arthritis (RA) in comparison with healthy controls and measured the erosion volume at metacarpal heads (MCPs).

METHODS

In this cross-sectional study, the reproducibility was first assessed by 3 HR-pQCT exams with repositioning in 14 patients with late RA and 14 healthy subjects. Then, HR-pQCT parameters were measured in a group of 93 patients with RA and 31 healthy controls. Two RA subgroups were distinguished: early RA (disease duration < or =2 years) (n=36) and late RA (n=57) and compared them to healthy controls.

RESULTS

The precision of the HR-pQCT volumetric measurements as assessed with coefficient of variation ranged from 0.7% to 1.8% in patients with late RA and from 0.6% to 1.4% in healthy subjects at MCPs. Total and trabecular vBMD and trabecular thickness were significantly decreased in patients with RA compared to healthy subjects and were significantly correlated to disease activity. The erosion volume was highly correlated to a semiquantitative assessment using the Outcome Measures in Rheumatoid Arthritis Clinical Trials (OMERACT) scoring system applied to the HR-pQCT slices.

CONCLUSIONS

This study demonstrated the good reproducibility of the HR-pQCT volumetric measurements at MCPs and confirmed the involvement of trabecular compartment in periarticular osteopoenia. Thus, HR-pQCT appears interesting to simultaneously assess differences in bone volumetric density, microarchitecture and erosions.

摘要

目的

一种新的高分辨率外周定量 CT(HR-pQCT)系统允许对骨微结构和体积骨密度(vBMD)进行体内评估,具有 82μm 的各向同性分辨率。使用该设备,评估了类风湿关节炎(RA)患者与健康对照组之间的微结构损伤,并测量了掌骨(MCP)头部的侵蚀体积。

方法

在这项横断面研究中,首先通过对 14 例晚期 RA 患者和 14 例健康受试者进行 3 次 HR-pQCT 检查和重新定位来评估可重复性。然后,在 93 例 RA 患者和 31 例健康对照组中测量了 HR-pQCT 参数。将 2 个 RA 亚组区分开来:早期 RA(病程<或=2 年)(n=36)和晚期 RA(n=57),并将其与健康对照组进行比较。

结果

HR-pQCT 体积测量的精密度以变异系数评估,在晚期 RA 患者中范围为 0.7%至 1.8%,在健康受试者中范围为 0.6%至 1.4%,在 MCP 处。RA 患者的总和小梁 vBMD 以及小梁厚度均明显低于健康受试者,且与疾病活动度显著相关。侵蚀体积与在 HR-pQCT 切片上应用类风湿关节炎临床试验疗效测量(OMERACT)评分系统进行的半定量评估高度相关。

结论

本研究证明了 MCP 处 HR-pQCT 体积测量的良好可重复性,并证实了关节周围骨质疏松症中小梁腔室的参与。因此,HR-pQCT 似乎很有兴趣同时评估骨体积密度、微结构和侵蚀的差异。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验