Suppr超能文献

体内静脉血 T1 测量采用反转恢复真实快速成像序列在儿童和成人中的应用。

In vivo venous blood T1 measurement using inversion recovery true-FISP in children and adults.

机构信息

Graduate Institute of Oncology, National Taiwan University, Taipei 100, Taiwan, Republic of China.

出版信息

Magn Reson Med. 2010 Oct;64(4):1140-7. doi: 10.1002/mrm.22484.

Abstract

A time-efficient method is described for in vivo venous blood T(1) measurement using multiphase inversion-recovery-prepared balanced steady-state free precession imaging. Computer simulations and validation experiments using a flow phantom were carried out to demonstrate the accuracy of the proposed method for measuring blood T(1) by taking advantage of the continuous inflow of fresh blood with longitudinal magnetization undisturbed by previous radiofrequency pulses. In vivo measurement of venous blood T(1) in the sagittal sinus was carried out in 26 healthy children and adults aged 7-39 years. The measured venous blood T(1) values decreased with age as a whole (P = 0.006) and were higher in females than males (P = 0.013), matching the expected developmental changes and gender differences in human hematocrit level. The estimated mean blood T(1) values were highly correlated with normal hematocrit levels across age and gender groups (Spearman's r = 0.93, P = 0.008). The longitudinal repeatability of this technique was 4.0% as measured by the within-subject coefficient of variation. The proposed multiphase inversion recovery-prepared balanced steady-state free precession imaging method is a feasible technique for fast (< 1 min) and reliable in vivo venous blood T(1) measurement and may serve as an index of hematocrit level in individual subjects.

摘要

一种利用多期反转恢复准备平衡稳态自由进动成像进行体内静脉血 T1 测量的高效方法。通过利用新鲜血液的连续流入,并且不受先前射频脉冲的影响,保持纵向磁化,该方法利用这一优势,进行了计算机模拟和使用血流体模的验证实验,以证明其测量血液 T1 的准确性。在 26 名 7-39 岁的健康儿童和成人中进行了矢状窦静脉血 T1 的体内测量。测量的静脉血 T1 值总体上随年龄下降(P = 0.006),女性高于男性(P = 0.013),与人类血细胞比容水平的预期发育变化和性别差异相匹配。估计的平均血液 T1 值与各年龄组和性别组的正常血细胞比容水平高度相关(Spearman's r = 0.93,P = 0.008)。该技术的纵向重复性通过个体内变异系数测量为 4.0%。所提出的多期反转恢复准备平衡稳态自由进动成像方法是一种快速(<1 分钟)、可靠的体内静脉血 T1 测量的可行技术,并且可以作为个体血细胞比容水平的指标。

相似文献

1
2
Quantification of arterial cerebral blood volume using multiphase-balanced SSFP-based ASL.
Magn Reson Med. 2012 Jul;68(1):130-9. doi: 10.1002/mrm.23218. Epub 2011 Nov 29.
3
In vivo blood T(1) measurements at 1.5 T, 3 T, and 7 T.
Magn Reson Med. 2013 Oct;70(4):1082-6. doi: 10.1002/mrm.24550. Epub 2012 Nov 21.
5
Fast measurement of blood T in the human carotid artery at 3T: Accuracy, precision, and reproducibility.
Magn Reson Med. 2017 Jun;77(6):2296-2302. doi: 10.1002/mrm.26325. Epub 2016 Jul 20.
6
Measurement of T1 of human arterial and venous blood at 7T.
Magn Reson Imaging. 2013 Apr;31(3):477-9. doi: 10.1016/j.mri.2012.08.008. Epub 2012 Oct 25.
7
Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI.
J Magn Reson Imaging. 2016 Dec;44(6):1673-1682. doi: 10.1002/jmri.25305. Epub 2016 May 18.

引用本文的文献

3
4
Developmental coupling of cerebral blood flow and fMRI fluctuations in youth.
Cell Rep. 2022 Mar 29;38(13):110576. doi: 10.1016/j.celrep.2022.110576.
9
Quantitative perfusion mapping with induced transient hypoxia using BOLD MRI.
Magn Reson Med. 2021 Jan;85(1):168-181. doi: 10.1002/mrm.28422. Epub 2020 Jul 27.
10
Developmental patterns of CBF and BOLD responses to visual stimulus.
J Cereb Blood Flow Metab. 2021 Mar;41(3):630-640. doi: 10.1177/0271678X20925303. Epub 2020 May 21.

本文引用的文献

2
Nonenhanced MR angiography.
Radiology. 2008 Jul;248(1):20-43. doi: 10.1148/radiol.2481071497.
3
Theoretical and experimental investigation of the VASO contrast mechanism.
Magn Reson Med. 2006 Dec;56(6):1261-73. doi: 10.1002/mrm.21072.
4
MR susceptometry for measuring global brain oxygen extraction.
Magn Reson Med. 2006 May;55(5):967-73. doi: 10.1002/mrm.20892.
6
T1, T2 relaxation and magnetization transfer in tissue at 3T.
Magn Reson Med. 2005 Sep;54(3):507-12. doi: 10.1002/mrm.20605.
7
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla.
Magn Reson Med. 2004 Sep;52(3):679-82. doi: 10.1002/mrm.20178.
8
Inversion recovery TrueFISP: quantification of T(1), T(2), and spin density.
Magn Reson Med. 2004 Apr;51(4):661-7. doi: 10.1002/mrm.20058.
9
Pediatric perfusion imaging using pulsed arterial spin labeling.
J Magn Reson Imaging. 2003 Oct;18(4):404-13. doi: 10.1002/jmri.10372.
10
Principles and applications of balanced SSFP techniques.
Eur Radiol. 2003 Nov;13(11):2409-18. doi: 10.1007/s00330-003-1957-x. Epub 2003 Aug 20.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验