Suppr超能文献

加权 ℓ1 无参考 PRF 位移测温法。

Reweighted ℓ1 referenceless PRF shift thermometry.

机构信息

Department of Electrical Engineering, Stanford University, Stanford, California, USA.

出版信息

Magn Reson Med. 2010 Oct;64(4):1068-77. doi: 10.1002/mrm.22502.

Abstract

Temperature estimation in proton resonance frequency (PRF) shift MR thermometry requires a reference, or pretreatment, phase image that is subtracted from image phase during thermal treatment to yield a phase difference image proportional to temperature change. Referenceless thermometry methods derive a reference phase image from the treatment image itself by assuming that in the absence of a hot spot, the image phase can be accurately represented in a smooth (usually low order polynomial) basis. By masking the hot spot out of a least squares (ℓ(2)) regression, the reference phase image's coefficients on the polynomial basis are estimated and a reference image is derived by evaluating the polynomial inside the hot spot area. Referenceless methods are therefore insensitive to motion and bulk main field shifts, however, currently these methods require user interaction or sophisticated tracking to ensure that the hot spot is masked out of the polynomial regression. This article introduces an approach to reference PRF shift thermometry that uses reweighted ℓ(1) regression, a form of robust regression, to obtain background phase coefficients without hot spot tracking and masking. The method is compared to conventional referenceless thermometry, and demonstrated experimentally in monitoring HIFU heating in a phantom and canine prostate, as well as in a healthy human liver.

摘要

在质子共振频率 (PRF) 偏移磁共振测温中,需要一个参考(或预处理)相位图像,该图像在热治疗期间从图像相位中减去,以产生与温度变化成正比的相位差图像。无参考测温方法通过假设在没有热点的情况下,图像相位可以用平滑(通常是低阶多项式)基准确表示,从处理图像本身推导出参考相位图像。通过从最小二乘(ℓ(2))回归中掩蔽热点,可以估计参考相位图像的多项式基系数,并通过在热点区域内评估多项式来得出参考图像。因此,无参考方法对运动和主磁场偏移不敏感,但是,目前这些方法需要用户交互或复杂的跟踪来确保将热点从多项式回归中掩蔽出来。本文介绍了一种使用加权 ℓ(1)回归(一种稳健回归形式)的参考 PRF 偏移测温方法,无需热点跟踪和掩蔽即可获得背景相位系数。该方法与传统的无参考测温方法进行了比较,并在模拟和犬前列腺以及健康人肝脏中进行了 HIFU 加热监测的实验中进行了演示。

相似文献

1
3
Referenceless PRF shift thermometry.无参考的光频域反射仪频移测温法
Magn Reson Med. 2004 Jun;51(6):1223-31. doi: 10.1002/mrm.20090.

引用本文的文献

1
Magnetic Resonance Acoustic Radiation Force Imaging (MR-ARFI).磁共振声辐射力成像(MR-ARFI)。
J Magn Reson Imaging. 2025 Jul;62(1):20-39. doi: 10.1002/jmri.29712. Epub 2025 Jan 22.
9
Multiple-point magnetic resonance acoustic radiation force imaging.多点磁共振声辐射力成像。
Magn Reson Med. 2019 Feb;81(2):1104-1117. doi: 10.1002/mrm.27477. Epub 2018 Sep 26.
10
Open-source, small-animal magnetic resonance-guided focused ultrasound system.开源小型动物磁共振引导聚焦超声系统
J Ther Ultrasound. 2016 Sep 5;4(1):22. doi: 10.1186/s40349-016-0066-7. eCollection 2016.

本文引用的文献

5
Referenceless PRF shift thermometry.无参考的光频域反射仪频移测温法
Magn Reson Med. 2004 Jun;51(6):1223-31. doi: 10.1002/mrm.20090.
6
Real-time cardiac MRI at 3 tesla.3特斯拉实时心脏磁共振成像
Magn Reson Med. 2004 Apr;51(4):655-60. doi: 10.1002/mrm.20053.