Schmid U, Kniestedt C
Augenklinik, Universitätsspital Zürich, Frauenklinikstrasse 24, 8091, Zürich, Switzerland.
Ophthalmologe. 2010 Jul;107(7):676-8, 680-2. doi: 10.1007/s00347-010-2175-y.
Goldmann applanation tonometry is still the gold standard of intraocular pressure measurement (IOP) and an essential part in the diagnosis of glaucoma. Applanation tonometry is usually performed on a sitting patient at the slit lamp. However, under certain circumstances it is necessary to measure the IOP outside the office setting. With handheld devices the measuring procedure is brought to bedside and surgery theatres, as well as to patients who are not able to sit behind the slit lamp. The dynamic contour tonometer (DCT) represents a new method of direct IOP measurement. Its physical principle is based on piezo-electronic contour matching tonometry and is claimed to be less dependent on biochemical properties of the cornea. Besides the IOP, the ocular pulse amplitude can also be measured. Until now, the DCT had been available as a slit lamp mounted device. In this report, we present a portable prototype of the device. In comparison with the Perkins tonometer and the TONO-PEN XL, the handheld DCT shows smaller intra- and inter-examiner variability. Additionally, the device offers the unique possibility to display the ocular pulse amplitude while the patient is in a horizontal position.
戈德曼压平眼压计仍然是眼压测量(IOP)的金标准,也是青光眼诊断的重要组成部分。压平眼压计通常在裂隙灯下对坐着的患者进行测量。然而,在某些情况下,需要在诊室以外的环境中测量眼压。使用手持设备,测量程序可以带到床边、手术室,也适用于无法坐在裂隙灯后的患者。动态轮廓眼压计(DCT)是一种直接测量眼压的新方法。其物理原理基于压电电子轮廓匹配眼压测量法,据称对角膜生化特性的依赖性较小。除了眼压,还可以测量眼脉搏振幅。到目前为止,DCT一直是作为一种安装在裂隙灯上的设备。在本报告中,我们展示了该设备的便携式原型。与帕金斯眼压计和TONO-PEN XL相比,手持式DCT在检查者内和检查者间的变异性更小。此外,该设备还提供了独特的可能性,即在患者处于水平位置时显示眼脉搏振幅。