Korea Research Institute of Standards and Science, 1 Doroyng-dong Yuseong-gu, Daejeon, South Korea.
Ultrasonics. 2010 Aug;50(8):790-7. doi: 10.1016/j.ultras.2010.04.001. Epub 2010 Apr 24.
This paper describes fabrication and comparison of PMN-PT single crystal, PZT, and PZT-based 1-3 composite ultrasonic transducers for NDE applications. As a front matching layer between test material (Austenite stainless steel, SUS316) and piezoelectric materials, alumina ceramics was selected. The appropriate acoustic impedance of the backing materials for each transducer was determined based on the results of KLM model simulation. Prototype ultrasonic transducers with the center frequencies of approximately 2.25 and 5MHz for contact measurement were fabricated and compared to each other. The PMN-PT single crystal ultrasonic transducer shows considerably improved performance in sensitivity over the PZT and PZT-based 1-3 composite ultrasonic transducers.
本文描述了 PMN-PT 单晶、PZT 和基于 PZT 的 1-3 复合材料超声换能器的制造和比较,用于无损检测应用。作为测试材料(奥氏体不锈钢,SUS316)和压电材料之间的前置匹配层,选择了氧化铝陶瓷。根据 KLM 模型仿真的结果,确定了每个换能器的背衬材料的适当声阻抗。制造了具有约 2.25MHz 和 5MHz 中心频率的接触测量用原型超声换能器,并对其进行了相互比较。PMN-PT 单晶超声换能器在灵敏度方面明显优于 PZT 和基于 PZT 的 1-3 复合材料超声换能器。