Taylor Katrina, Gleason Carol
Veterinary Science, Bristol-Myers Squibb Research and Development, Syracuse, New York, USA.
J Am Assoc Lab Anim Sci. 2010 May;49(3):352-6.
Electrocardiograms (ECGs) often are collected from sedated cynomolgus macaques (Macaca fascicularis) in drug safety studies to support investigational new drug applications. ECGs are evaluated either manually or electronically, and the quality of the ECG tracing can affect the quality of that evaluation. The body position of the subject sometimes is manipulated to eliminate noise or clarify ECG complex morphology, and typically multiple technicians collect ECG data over time. Both factors-body position and multiple technicians-could affect ECG quality. This study was designed to determine whether body position or multiple technicians affects heart rate, mean electrical axis, or ECG parameters (RR interval, P wave duration, PR interval, QRS duration, QT interval (uncorrected and rate-corrected by using the Bazett [QTcb] and Fridericia [QTcf] formulas), P wave amplitude, R wave amplitude, T wave height, T wave height negative, and ST segment elevation). The results reveal minimal (coefficient of variation [CV] less than 10%) within-animal variation between body positions (ventral, dorsal, right or left lateral), with the exception of P wave amplitude (17.5%), R wave amplitude (23.7%), and ST segment elevation (43%). Minimal variation in ECG parameters (no more than 7%) was detected between technicians, across animals, and across body positions. These findings suggest that neither a change in body position to increase the quality of an ECG tracing nor the use of multiple technicians significantly affect the evaluation of quantitative ECG parameters, especially QTcb (0.1% CV) and QTcf (1.3% CV).
在药物安全性研究中,常从镇静的食蟹猴(猕猴)采集心电图(ECG)以支持研究性新药申请。ECG评估可手动或电子进行,而ECG描记的质量会影响评估质量。有时会调整受试者的体位以消除噪声或明确ECG复合波形态,且通常会有多名技术人员随时间收集ECG数据。这两个因素——体位和多名技术人员——都可能影响ECG质量。本研究旨在确定体位或多名技术人员是否会影响心率、平均电轴或ECG参数(RR间期、P波时限、PR间期、QRS时限、QT间期(未校正以及使用Bazett公式[QTcb]和Fridericia公式[QTcf]进行心率校正)、P波振幅、R波振幅、T波高度、负向T波高度以及ST段抬高)。结果显示,除P波振幅(17.5%)、R波振幅(23.7%)和ST段抬高(43%)外,动物在不同体位(腹侧、背侧、右侧或左侧卧位)之间的个体内差异极小(变异系数[CV]小于10%)。在技术人员之间、不同动物之间以及不同体位之间,ECG参数的变化极小(不超过7%)。这些发现表明,无论是改变体位以提高ECG描记质量,还是使用多名技术人员,均不会显著影响定量ECG参数的评估,尤其是QTcb(CV为0.1%)和QTcf(CV为1.3%)。