Suppr超能文献

Measurements of nonlinear refractive index in scattering media.

作者信息

Samineni Prathyush, Perret Zachary, Warren Warren S, Fischer Martin C

机构信息

Department of Chemistry, Duke University, Durham, NC 27708, USA.

出版信息

Opt Express. 2010 Jun 7;18(12):12727-35. doi: 10.1364/OE.18.012727.

Abstract

We have recently developed a spectral re-shaping technique to simultaneously measure nonlinear refractive index and nonlinear absorption. In this technique, the information about the nonlinearities is encoded in the frequency domain, rather than in the spatial domain as in the conventional Z-scan method. Here we show that frequency encoding is much more robust with respect to scattering. We compare spectral re-shaping and Z-scan measurements in a highly scattering environment and show that reliable spectral re-shaping measurements can be performed even in a regime that precludes standard Z-scans.

摘要

相似文献

1
Measurements of nonlinear refractive index in scattering media.
Opt Express. 2010 Jun 7;18(12):12727-35. doi: 10.1364/OE.18.012727.
5
6
Nonlinear absorption and scattering of a single plasmonic nanostructure characterized by -scan technique.
Beilstein J Nanotechnol. 2019 Nov 6;10:2182-2191. doi: 10.3762/bjnano.10.211. eCollection 2019.
7
Dispersion of nonlinear refraction and two-photon absorption using a white-light continuum Z-scan.
Opt Express. 2005 May 16;13(10):3594-9. doi: 10.1364/opex.13.003594.
9
Methodical inaccuracy of the Z-scan method for few-cycle terahertz pulses.
Sci Rep. 2019 Jun 24;9(1):9146. doi: 10.1038/s41598-019-45735-6.

引用本文的文献

2
Invited Review Article: Pump-probe microscopy.
Rev Sci Instrum. 2016 Mar;87(3):031101. doi: 10.1063/1.4943211.
4
Pump-probe nonlinear phase dispersion spectroscopy.
Opt Express. 2013 Apr 22;21(8):9353-64. doi: 10.1364/OE.21.009353.
5
Cross-phase modulation spectral shifting: nonlinear phase contrast in a pump-probe microscope.
Biomed Opt Express. 2012 May 1;3(5):854-62. doi: 10.1364/BOE.3.000854. Epub 2012 Apr 4.
6
Cross-phase modulation imaging.
Opt Lett. 2012 Mar 1;37(5):800-2. doi: 10.1364/OL.37.000800.

本文引用的文献

1
Z-scan measurement technique for non-Gaussian beams and arbitrary sample thicknesses.
Opt Lett. 1995 Sep 1;20(17):1821. doi: 10.1364/ol.20.001821.
2
Femtosecond laser pulse shaping by use of microsecond radio-frequency pulses.
Opt Lett. 1994 May 15;19(10):737-9. doi: 10.1364/ol.19.000737.
3
Eclipsing Z-scan measurement of lambda/10(4) wave-front distortion.
Opt Lett. 1994 Mar 1;19(5):317-9. doi: 10.1364/ol.19.000317.
4
Nonlinear refraction in vitreous humor.
Opt Lett. 1993 Nov 1;18(21):1792-4. doi: 10.1364/ol.18.001792.
5
High-sensitivity, single-beam n(2) measurements.
Opt Lett. 1989 Sep 1;14(17):955-7. doi: 10.1364/ol.14.000955.
6
Stimulated parametric emission microscopy.
Opt Express. 2006 Jan 23;14(2):786-93. doi: 10.1364/opex.14.000786.
7
9
Self-phase modulation signatures of neuronal activity.
Opt Lett. 2008 Feb 1;33(3):219-21. doi: 10.1364/ol.33.000219.
10
Second-harmonic tomography of tissues.
Opt Lett. 1997 Sep 1;22(17):1323-5. doi: 10.1364/ol.22.001323.

文献AI研究员