Suppr超能文献

在模拟牙髓压力下一年水储存期间牙本质结合降解的缓慢进展。

Slow progression of dentin bond degradation during one-year water storage under simulated pulpal pressure.

机构信息

Department of Dentistry, School of Dentistry, Federal University of Santa Catarina, Florianópolis, Santa Catarina, Brazil.

出版信息

J Dent. 2010 Oct;38(10):802-10. doi: 10.1016/j.jdent.2010.06.012. Epub 2010 Jul 3.

Abstract

OBJECTIVES

To evaluate the dentin bond durability of simplified adhesives after one-year (1 y) under water storage and simulated pulpal pressure.

METHODS

Class I cavities were prepared in sixty human third molars with the pulpal wall located in mid-coronal dentin. The roots were cut off to expose the pulpal chamber, and the teeth were assembled in a pulpal pressure simulator device. A two-step etch-and-rinse adhesive (Single Bond 2/SB), a two-step self-etch adhesive (Clearfil SE Bond/CSE), a three-step self-etch adhesive (Adper Scotchbond SE/SSE) and three all-in-one adhesives (Adper Easy Bond/EB, Clearfil S(3) Bond/S3 and Adhese One/AO) were applied according to manufacturers instructions. No enamel pre-etching was used for the self-etch systems. The cavities were filled with a composite (Z250, 3M ESPE) in four to five horizontal increments and individually cured. Immediately after the final cure, pulpal pressure was set to 15 cm H(2)O. After 24 h and 1 y under simulate pulpal pressure the teeth were cut following a 'nontrimming' microtensile test technique (n=30) and tested in tension. Kruskall-Wallis and post hoc multiple comparisons were used at alpha=0.05. Weibull statistics was applied to SB, CSE and EB. Fractographic analysis of debonded specimens was performed using scanning electron microscopy.

RESULTS

At 24 h and 1 y periods, SB showed higher bond strength means than all the others adhesives tested. CSE was not statistically different from EB at 24 h and from EB and SB at 1 y. EB showed bond strength statistically higher than the other three self-etch adhesives, which were not statistically different from each other at 24 h. AO showed significantly lower bond strength than all tested materials after 1 y. For all adhesives the mean bond strength at 1 y were not statistically different from the values measured at 24 h (p>0.05). Shifts in failure mode patterns and Weibull modulus decrease indicate some degree of bond degradation after the 1 y storage period.

CONCLUSION

One-year of simulated pulpal pressure did not affect dentin bond strength of simplified adhesives in Class I restorations. Signs of degradation were only revealed by fractographic analysis and reliability parameters.

摘要

目的

评估简化型黏结剂在经过一年水储存和模拟牙髓压力后的牙本质黏结耐久性。

方法

在 60 个人类第三磨牙的 I 类窝洞中进行实验,牙髓壁位于近中牙本质中部。将牙根切断以暴露牙髓腔,并将牙齿组装在牙髓压力模拟器装置中。按照制造商的说明,使用两步酸蚀-冲洗黏结剂(Single Bond 2/SB)、两步自酸蚀黏结剂(Clearfil SE Bond/CSE)、三步自酸蚀黏结剂(Adper Scotchbond SE/SSE)和三种一体化黏结剂(Adper Easy Bond/EB、Clearfil S(3) Bond/S3 和 Adhese One/AO)。自酸蚀系统未进行釉质预酸蚀。用复合树脂(Z250,3M ESPE)以四到五个水平增量分层填充,并单独固化。在最后一次固化后,立即将牙髓压力设定为 15 cm H(2)O。在模拟牙髓压力下 24 h 和 1 年后,根据“无修剪”微拉伸测试技术(n=30)将牙齿切割,并进行拉伸测试。采用 Kruskal-Wallis 和事后多重比较(alpha=0.05)。对 SB、CSE 和 EB 进行 Weibull 统计分析。使用扫描电子显微镜对离解的样本进行断口分析。

结果

在 24 h 和 1 年时,SB 的黏结强度均值高于其他所有测试黏结剂。CSE 在 24 h 时与 EB 无统计学差异,在 1 年时与 EB 和 SB 无统计学差异。EB 的黏结强度显著高于其他三种自酸蚀黏结剂,24 h 时它们之间无统计学差异。1 年后,AO 的黏结强度明显低于所有测试材料。所有黏结剂在 1 年后的平均黏结强度与 24 h 时测量值无统计学差异(p>0.05)。失效模式的变化和 Weibull 模量的降低表明,经过 1 年的储存后,黏结强度有一定程度的下降。

结论

在 I 类修复体中,模拟牙髓压力 1 年对简化型黏结剂的牙本质黏结强度没有影响。只有通过断口分析和可靠性参数才能发现降解的迹象。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验