Suppr超能文献

埃塞俄比亚亚的斯亚贝巴成人后前位(PA)胸部X光检查的当地诊断参考水平。

Local diagnostic reference levels for adult posteroanterior (PA) chest x-ray examination in Addis Ababa, Ethiopia.

作者信息

Teferi Seife, Admassie Daniel, Worku Alemayehu, Zewdeneh Daniel

机构信息

Department of Radiology, Medical Faculty, AAU.

出版信息

Ethiop Med J. 2010 Jan;48(1):49-55.

Abstract

BACKGROUND

The Local Diagnostic Reference Levels (LDRLs) form an efficient, concise and powerful standard for optimizing the radiation protection of a patient.

OBJECTIVES

To calculate the Entrance Surface Doses (ESDs) received by patients undergoing PA chest X-ray examinations in major public hospitals in Addis Ababa, thereby to establish the first Ethiopian LDRLs as part of ongoing dose reduction program.

MATERIALS AND METHODS

The entrance dose in air per examination was measured in eight hospitals comprising nine X-ray units and a sample of 192 radiographs. The entrance dose in air was measured using dositime dx X-ray Digital Dosimeter and Exposure Time Meter. The data were analyzedstatistically, and the minimum, median, mean, maximum, and third quartile values of ESDs are reported Finally, the proposed LDRLs are compared with the international reference dose values reported by the Commission for European Community (CEC), the International Atomic Energy Agency (IAEA) and the National Radiological Protection Board (NRPB).

RESULTS

The third quartile value of the distribution of mean doses at individual hospitals participating in this survey is found to be 1.08 milligray (mGy). Hospitals mean ESDs for PA chest X-ray examination is found with the range of 0.0.76 to 1.48 mGy. Most of the ESD measured doses were slightly greater than the NRPB, CEC and IAEA reference doses.

CONCLUSION

The results of the present study indicate a need for Quality Assurance (QA) programs to be undertaken to avert considerable cost and high patient doses. The results are useful to national and professional organizations and can be used as a baseline upon which future dose measurements may be compared.

摘要

背景

当地诊断参考水平(LDRLs)构成了优化患者辐射防护的高效、简洁且有力的标准。

目的

计算亚的斯亚贝巴各大公立医院接受后前位胸部X线检查患者所接受的体表入射剂量(ESDs),从而制定首个埃塞俄比亚LDRLs,作为正在进行的剂量降低计划的一部分。

材料与方法

在包括9个X线设备的8家医院对192份X线片样本进行每次检查时空气中的入射剂量测量。使用剂量时间dx X线数字剂量仪和曝光时间计测量空气中的入射剂量。对数据进行统计分析,报告ESDs的最小值、中位数、平均值、最大值和第三四分位数。最后,将提议的LDRLs与欧洲共同体委员会(CEC)、国际原子能机构(IAEA)和国家放射防护委员会(NRPB)报告的国际参考剂量值进行比较。

结果

参与本次调查的各医院平均剂量分布的第三四分位数为1.08毫戈瑞(mGy)。后前位胸部X线检查的医院平均ESDs范围为0.76至1.48 mGy。大多数测量的ESDs剂量略高于NRPB、CEC和IAEA的参考剂量。

结论

本研究结果表明需要开展质量保证(QA)计划,以避免高额成本和患者高剂量。该结果对国家和专业组织有用,可作为未来剂量测量比较的基线。

相似文献

3
4
[CR (Computed Radiography)].
Igaku Butsuri. 2002;22(2):110-7.
5
Entrance surface doses to patients undergoing selected diagnostic X-ray examinations in Sudan.
Radiat Prot Dosimetry. 2007;123(2):209-14. doi: 10.1093/rpd/ncl137. Epub 2006 Sep 14.
6
Management of patient doses and diagnostic reference levels in X-ray radiography in Lithuania.
Radiat Prot Dosimetry. 2010 Apr-May;139(1-3):313-6. doi: 10.1093/rpd/ncq102. Epub 2010 Mar 8.
8
Results of a patient dose survey on diagnostic radiology in Lithuania.
Radiat Prot Dosimetry. 2005;114(1-3):172-5. doi: 10.1093/rpd/nch529.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验