Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria.
J Urol. 2010 Sep;184(3):913-7. doi: 10.1016/j.juro.2010.05.026.
We assessed the prostate cancer detection rate of real-time elastography targeted biopsy in men with total prostate specific antigen 1.25 ng/ml or greater and 4.00 ng/ml or less.
Real-time elastography using an EUB 8500 Hitachi ultrasound system (Hitachi Medical, Tokyo, Japan) was done in 94 men with a mean age of 57.4 years (range 35 to 77) with increased prostate specific antigen between 1.25 ng/ml or greater and 4.00 ng/ml or less (mean 3.20, range 1.30 to 4.00) and a free-to-total prostate specific antigen ratio of less than 18%. Real-time elastography was done to evaluate peripheral zone tissue elasticity and hard areas were defined as suspicious. Targeted biopsies with a maximum of 5 cores were done in suspicious areas, followed by 10-core systematic biopsy. We analyzed the cancer detection rate of real-time elastography and systematic biopsy.
Cancer was found in 27 of 94 patients (28.7%). Real-time elastography detected cancer in 20 patients (21.3%) and systematic biopsy detected it in 18 (19.1%). Positive cancer cores were found in real-time elastography targeted cores in 38 of 158 cases (24%) and in systematic cores in 38 of 752 (5.1%) (chi-square test p <0.0001). The cancer detection rate per core was 4.7-fold greater for targeted than for systematic biopsy.
Real-time elastography targeted biopsy allows prostate cancer detection in men with prostate specific antigen 1.25 ng/ml or greater and 4 ng/ml or less with a decreased number of cores compared with that of systematic biopsy.
我们评估了实时弹性成像靶向活检在总前列腺特异性抗原(PSA)为 1.25ng/ml 或以上且 4.00ng/ml 或以下的男性中的前列腺癌检出率。
使用 EUB 8500 日立超声系统(日立医疗,日本东京)对 94 名年龄在 35 至 77 岁之间、平均年龄为 57.4 岁的男性进行了实时弹性成像检查。这些男性的 PSA 水平在 1.25ng/ml 或以上且 4.00ng/ml 或以下之间(平均为 3.20ng/ml,范围为 1.30 至 4.00ng/ml),游离 PSA 与总 PSA 的比值小于 18%。实时弹性成像用于评估外周带组织的弹性,硬区域被定义为可疑区域。在可疑区域进行最大 5 针靶向活检,然后进行 10 针系统活检。我们分析了实时弹性成像和系统活检的癌症检出率。
94 例患者中有 27 例(28.7%)发现癌症。实时弹性成像检测到 20 例(21.3%)癌症,系统活检检测到 18 例(19.1%)。在 158 例实时弹性成像靶向活检中,38 例(24%)发现阳性癌核心,在 752 例系统活检中,38 例(5.1%)发现阳性癌核心(卡方检验,p <0.0001)。靶向活检的每针癌症检出率是系统活检的 4.7 倍。
与系统活检相比,实时弹性成像靶向活检可在 PSA 为 1.25ng/ml 或以上且 4ng/ml 或以下的男性中以较少的活检针数检测到前列腺癌。