Comparison of image acquisition and radiologist interpretation times in a diagnostic mammography center.

机构信息

Department of Radiology, University of North Carolina Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-7510, USA.

出版信息

Acad Radiol. 2010 Sep;17(9):1168-74. doi: 10.1016/j.acra.2010.04.018. Epub 2010 Jun 19.

Abstract

RATIONALE AND OBJECTIVES

The purpose of this study was to determine the acquisition and interpretation times of screen-film mammography and soft-copy digital mammography in a diagnostic mammography center.

MATERIALS AND METHODS

The study was conducted in three phases for patients presenting for clinical diagnostic workup to a mammography clinic. In the first phase, technologist acquisition and processing times and radiologist interpretation time were measured for patients imaged with a screen-film mammographic system. During the second phase of the study, times were measured for patients imaged with a direct radiographic digital mammographic system, with interpretation performed on a soft-copy display system. During the third phase, 3 months after installation of the soft-copy display system, times were measured again for patients imaged on the same direct radiographic digital mammographic system, with interpretation with the same soft-copy system. The same four experienced breast imaging radiologists and seven technologists participated in all phases of the study. All data were entered into a database, and statistical analysis was conducted using weighted linear models and logarithmic transformation.

RESULTS

Times were obtained for 295 patients. There were 100 patients each for phases 1 and 2 and 95 patients for phase 3. Diagnostic mammographic acquisition times with processing were 13.02 min/case for screen film (phase 1), 8.16 min/case for digital (phase 2), and 10.66 min/case for digital (phase 3) (P < .001 and P < .0001, respectively). In addition, the radiologist interpretation time for digital mammography in both phases was not significantly different from that for film mammography (P = .2853 and P = .2893, respectively). There was no significant difference between phases 2 and 3 (P = 1.0000). The mean interpretation times were 3.75 min/case for screen film, 2.14 min/case for digital (phase 2), and 2.26 min/case for digital (phase 3).

CONCLUSIONS

Digital mammography significantly shortened the acquisition time for diagnostic mammography. There was no significant difference in interpretation time compared to screen-film mammography in a diagnostic mammography setting.

摘要

背景与目的

本研究旨在确定诊断性乳房 X 光摄影中心屏片乳房 X 光摄影和软拷贝数字乳房 X 光摄影的获取和解释时间。

材料与方法

本研究分三个阶段对就诊于乳房 X 光摄影诊所的患者进行,每一阶段都有不同的研究内容。第一阶段,对使用屏片乳房 X 光摄影系统成像的患者测量技术员的获取和处理时间以及放射科医师的解释时间。在研究的第二阶段,对使用直接射线数字化乳房 X 光摄影系统成像的患者测量时间,使用软拷贝显示系统进行解释。在第三阶段,在安装软拷贝显示系统 3 个月后,对使用同一直接射线数字化乳房 X 光摄影系统成像的患者再次测量时间,使用相同的软拷贝系统进行解释。所有阶段都有四位经验丰富的乳房影像学放射科医师和七位技术员参与。所有数据都输入数据库,使用加权线性模型和对数转换进行统计分析。

结果

共获得 295 例患者的数据。各阶段的患者数分别为 100 例(第 1 阶段和第 2 阶段)和 95 例(第 3 阶段)。屏片(第 1 阶段)的诊断性乳房 X 光摄影获取时间为 13.02 分钟/例,数字(第 2 阶段)为 8.16 分钟/例,数字(第 3 阶段)为 10.66 分钟/例(P<.001 和 P<.0001)。此外,在两个阶段的数字乳房 X 光摄影中,放射科医师的解释时间与胶片乳房 X 光摄影相比没有显著差异(P=0.2853 和 P=0.2893)。第 2 阶段和第 3 阶段之间没有显著差异(P=1.0000)。平均解释时间分别为屏片 3.75 分钟/例,数字(第 2 阶段)2.14 分钟/例,数字(第 3 阶段)2.26 分钟/例。

结论

数字乳房 X 光摄影显著缩短了诊断性乳房 X 光摄影的获取时间。在诊断性乳房 X 光摄影环境中,与屏片乳房 X 光摄影相比,解释时间没有显著差异。