Department of Ophthalmology, Yeditepe University Medical Faculty, Yeditepe University, Istanbul, Turkey.
Cornea. 2010 Nov;29(11):1247-51. doi: 10.1097/ICO.0b013e3181ca6383.
To examine the biomechanical properties of keratoconic eyes following penetrating keratoplasty and to compare results with the biomechanical characteristics of manifest keratoconus, forme fruste keratoconus and normal eyes as measured with the Reichert ocular response analyzer (ORA).
This retrospective analysis comprised a total of 169 eyes: 34 eyes with forme fruste keratoconus (group FF), 36 eyes with manifest keratoconus (Group KC), 36 eyes that have undergone penetrating keratoplasty (Group PK) and a control group of 63 normal eyes (Group N). Corneal hysteresis (CH), corneal resistance factor (CRF), corneal compensated intraocular pressure, and Goldmann correlated intraocular pressure were measured by ORA. Central corneal thickness was calculated by the integrated handheld ultrasonic pachymeter of the ORA. The statistical analysis focused on CH and CRF changes among the 4 groups.
When compared with normal eyes, mean CH and CRF values were found significantly lower in all groups (P < 0.05). Mean CH values were 8.19 ± 1.49 mm Hg in Group KC, 9.21 ± 1.38 mm Hg in Group FF, 10.16 ± 1.93 mm Hg in Group PK, and 11.43 ± 1.52 mm Hg in normal eyes (Group N). Although there was not a significant difference in mean CH values between Groups PK and FF (P = 0.072), the difference was significant between Groups KC as well as FF and Groups KC and PK (P < 0.05). Mean CRF values were found as 6.79 ± 1.81 mm Hg (Group KC), 8.21 ± 1.64 mm Hg (Group FF), 9.94 ± 2.34 mm Hg (Group PK), and 11.53 ± 1.83 mm Hg in Group N. The difference was statistically significant among all groups (P < 0.05).
Penetrating keratoplasty has a beneficial effect on corneal biomechanics in keratoconic eyes. CH and CRF parameters approach the range of normal eyes after corneal transplantation.
研究穿透性角膜移植术后圆锥角膜眼的生物力学特性,并与应用 Reichert 眼前节分析仪(ORA)测量的临床前期圆锥角膜、临床期圆锥角膜、正常眼的生物力学特征进行比较。
本回顾性分析共纳入 169 只眼:临床前期圆锥角膜 34 只眼(FF 组)、临床期圆锥角膜 36 只眼(KC 组)、穿透性角膜移植术后 36 只眼(PK 组)和正常对照组 63 只眼(N 组)。应用 ORA 测量角膜滞后量(CH)、角膜阻力因子(CRF)、角膜补偿眼压和 Goldmann 相关眼压。应用 ORA 集成的手持超声角膜测厚仪计算中央角膜厚度。统计学分析重点关注 4 组间 CH 和 CRF 的变化。
与正常眼相比,所有组的 CH 和 CRF 值均显著降低(P < 0.05)。KC 组 CH 值为 8.19 ± 1.49mmHg,FF 组为 9.21 ± 1.38mmHg,PK 组为 10.16 ± 1.93mmHg,N 组为 11.43 ± 1.52mmHg。PK 组与 FF 组的 CH 值差异无统计学意义(P = 0.072),但 KC 组与 FF 组、KC 组与 PK 组之间的 CH 值差异均有统计学意义(P < 0.05)。KC 组 CRF 值为 6.79 ± 1.81mmHg,FF 组为 8.21 ± 1.64mmHg,PK 组为 9.94 ± 2.34mmHg,N 组为 11.53 ± 1.83mmHg。所有组间 CRF 值差异均有统计学意义(P < 0.05)。
穿透性角膜移植术对圆锥角膜眼的角膜生物力学有有益的影响。角膜移植术后 CH 和 CRF 参数接近正常眼范围。