Suppr超能文献

超声辅助基质固相分散萃取在牛奶中环丙沙星残留的 HPLC 确证检测中的应用。

Application of ultrasound-assisted matrix solid-phase dispersion extraction to the HPLC confirmatory determination of cephalosporin residues in milk.

机构信息

Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, Thessaloniki, Greece.

出版信息

J Sep Sci. 2010 Sep;33(17-18):2862-71. doi: 10.1002/jssc.201000385.

Abstract

Ultrasound-assisted matrix solid-phase dispersion (MSPD) was applied to isolate eight cephalosporins (cefadroxil, cefaclor, cephalexin, cefotaxime, cefazolin, cefuroxime, cefoperazone and ceftiofur) from milk. Multi-residue analysis was subsequently performed by HPLC-diode array detection. Extraction yield by matrix solid-phase dispersion using Nexus sorbent was higher than various investigated SPE protocols. Three analytical columns, two conventional silica based and one monolithic, were compared based on resolution, peak shape and retention time. The optimum method using Chromolith RP-18e (100×4.6 mm) achieved separation in less than 16 min. Method validation was performed according to the European Union Decision 2002/657/EC, determining linearity, selectivity, stability, decision limit, detection capability, accuracy and precision. RSD values observed were lower than 15.3%. Recovery rates of examined antimicrobials from milk ranged from 93.8 to 101.9% for cefadroxil, from 94.7 to 103.6% for cefaclor, from 93.4 to 106.6% for cephalexine, from 104.1 to 115.3% for cefotaxime, from 97.1 to 105.6% for cefazolin, from 97.4 to 108.6% for cefuroxime, from 98.8 to 103.4% for cefoperazone and from 95.5 to 103.6% for ceftiofur. Correlation coefficients ranged from 0.9926 to 0.9999. CC(b) values were in the range from 103.5 to 112.3 μg/kg for analytes with a maximum residue limit of 100 μg/kg and from 54.4 to 56.3 μg/kg for those with a maximum residue limit of 50 μg/kg.

摘要

超声辅助基质固相分散(MSPD)用于从牛奶中分离八种头孢菌素(头孢羟氨苄、头孢克洛、头孢氨苄、头孢噻肟、头孢唑林、头孢呋辛、头孢哌酮和头孢噻呋)。随后通过高效液相色谱-二极管阵列检测进行多残留分析。使用 Nexus 吸附剂进行基质固相分散的提取产率高于各种研究的 SPE 方案。根据分辨率、峰形和保留时间比较了三种分析柱,两种常规硅胶柱和一种整体柱。使用 Chromolith RP-18e(100×4.6mm)的最佳方法在不到 16 分钟内实现了分离。根据欧盟 2002/657/EC 号决定进行方法验证,确定了线性度、选择性、稳定性、决策限、检测能力、准确度和精密度。观察到的 RSD 值低于 15.3%。从牛奶中检查的抗生素的回收率范围为头孢羟氨苄 93.8%至 101.9%,头孢克洛 94.7%至 103.6%,头孢氨苄 93.4%至 106.6%,头孢噻肟 104.1%至 115.3%,头孢唑林 97.1%至 105.6%,头孢呋辛 97.4%至 108.6%,头孢哌酮 98.8%至 103.4%,头孢噻呋 95.5%至 103.6%。相关系数范围为 0.9926 至 0.9999。CC(b) 值范围为 103.5 至 112.3μg/kg,用于最大残留限量为 100μg/kg 的分析物,54.4 至 56.3μg/kg,用于最大残留限量为 50μg/kg 的分析物。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验