Suppr超能文献

肌肉疲劳与肌电图测量的校准。

Muscle fatigue and calibration of EMG measurements.

机构信息

Department of Biomechanics and Orthopaedic Technology, University College of Health Sciences, Jönköping, Sweden.

出版信息

J Electromyogr Kinesiol. 1995 Dec;5(4):239-43.

Abstract

Amplitude electromyography (EMG) is often used as an estimator of muscular load. Such measurements can, however, be biased by other factors, for example muscular fatigue. The aim of this study was to examine the influence of fatigue on amplitude parameters of the EMG. The test subjects raised the arm to 90(9) of abduction in the plane of the scapula. The hand was loaded with 0, 1 and 2 kg during 5, 3 and 2 min respectively. EMG was recorded from the trapezius muscle, and spectral and amplitude parameters were calculated. There was a significant rise of the EMG amplitude as a sign of fatigue at all load levels: 7% min(-1) at 0 kg, 15% min(-1) at 1 kg, and 19% min(-1) at 2 kg. At 0 kg hand load there was no change of the spectral parameters but at higher load levels there was a significant decline of mean power frequency: 3% min(-1) at 1 kg and 11% at 2 kg. The amplitude rise due to muscle fatigue may seriously jeopardize calibration measurements unless the duration of the load is kept limited.

摘要

肌电图(EMG)幅度常用于肌肉负荷的估计。然而,这些测量可能会受到其他因素的影响,例如肌肉疲劳。本研究旨在研究疲劳对 EMG 幅度参数的影响。测试对象将手臂抬高至肩胛骨平面的 90°(9)外展。手在 5、3 和 2 分钟内分别加载 0、1 和 2 公斤。从斜方肌记录肌电图,并计算频谱和幅度参数。在所有负荷水平下,随着疲劳的出现,EMG 幅度都有显著升高:0 公斤时为 7% min(-1),1 公斤时为 15% min(-1),2 公斤时为 19% min(-1)。在 0 公斤的手部负荷下,频谱参数没有变化,但在较高的负荷水平下,平均功率频率显著下降:1 公斤时为 3% min(-1),2 公斤时为 11%。由于肌肉疲劳导致的幅度增加可能会严重危及校准测量,除非保持负荷时间有限。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验