Suppr超能文献

3 电荷耦合器件相机辅助腹腔镜部分肾切除术的视觉增强:通过可见血红蛋白光谱响应评估术中组织灌注和血管解剖结构。

Visual enhancement of laparoscopic partial nephrectomy with 3-charge coupled device camera: assessing intraoperative tissue perfusion and vascular anatomy by visible hemoglobin spectral response.

机构信息

Department of Regenerative Medicine, Combat Casualty Care, Naval Medical Research Center, Uniformed Services University, Silver Spring, Maryland 20910, USA.

出版信息

J Urol. 2010 Oct;184(4):1279-85. doi: 10.1016/j.juro.2010.06.010. Epub 2010 Aug 17.

Abstract

PURPOSE

We report the novel use of 3-charge coupled device camera technology to infer tissue oxygenation. The technique can aid surgeons to reliably differentiate vascular structures and noninvasively assess laparoscopic intraoperative changes in renal tissue perfusion during and after warm ischemia.

MATERIALS AND METHODS

We analyzed select digital video images from 10 laparoscopic partial nephrectomies for their individual 3-charge coupled device response. We enhanced surgical images by subtracting the red charge coupled device response from the blue response and overlaying the calculated image on the original image. Mean intensity values for regions of interest were compared and used to differentiate arterial and venous vasculature, and ischemic and nonischemic renal parenchyma.

RESULTS

The 3-charge coupled device enhanced images clearly delineated the vessels in all cases. Arteries were indicated by an intense red color while veins were shown in blue. Differences in mean region of interest intensity values for arteries and veins were statistically significant (p >0.0001). Three-charge coupled device analysis of pre-clamp and post-clamp renal images revealed visible, dramatic color enhancement for ischemic vs nonischemic kidneys. Differences in the mean region of interest intensity values were also significant (p <0.05).

CONCLUSIONS

We present a simple use of conventional 3-charge coupled device camera technology in a way that may provide urological surgeons with the ability to reliably distinguish vascular structures during hilar dissection, and detect and monitor changes in renal tissue perfusion during and after warm ischemia.

摘要

目的

我们报告了一种使用三电荷耦合器件(CCD)相机技术来推断组织氧合的新方法。该技术可以帮助外科医生可靠地区分血管结构,并在腹腔镜肾部分切除术中,非侵入性地评估热缺血期间和之后的肾组织灌注的变化。

材料与方法

我们分析了 10 例腹腔镜肾部分切除术的选定数字视频图像,以获取其各自的三电荷耦合器件响应。我们通过从蓝色电荷耦合器件响应中减去红色电荷耦合器件响应,并将计算出的图像叠加在原始图像上,从而增强了手术图像。比较了感兴趣区域的平均强度值,用于区分动脉和静脉血管以及缺血和非缺血的肾实质。

结果

三电荷耦合器件增强图像在所有情况下都清晰地描绘了血管。动脉呈现强烈的红色,而静脉显示为蓝色。动脉和静脉的感兴趣区域平均强度值差异具有统计学意义(p>0.0001)。在术前和术后夹闭的肾图像的三电荷耦合器件分析中,缺血肾与非缺血肾的颜色增强明显,差异具有统计学意义(p<0.05)。

结论

我们提出了一种简单的使用常规三电荷耦合器件相机技术的方法,这可能使泌尿科医生能够在肾门解剖时可靠地区分血管结构,并在热缺血期间和之后检测和监测肾组织灌注的变化。

相似文献

本文引用的文献

5
Feasibility and outcomes of repeat partial nephrectomy.重复部分肾切除术的可行性及结果
J Urol. 2008 Jul;180(1):89-93; discussion 93. doi: 10.1016/j.juro.2008.03.030. Epub 2008 May 15.
9
5-Year outcomes of laparoscopic partial nephrectomy.腹腔镜部分肾切除术的5年疗效
J Urol. 2007 Jan;177(1):70-4; discussion 74. doi: 10.1016/j.juro.2006.08.093.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验