Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou, 310058, China.
Anal Chem. 2010 Oct 1;82(19):8361-6. doi: 10.1021/ac101902c.
This paper describes a simple, robust, and integrated microchip-based system for droplet analysis with electrospray ionization-mass spectrometry (ESI-MS) detection. The microchip integrated multiple modules including a droplet generator, a droplet extraction interface, and a monolithic ESI emitter. The novel droplet extraction interface based on hydrophilic tongue structure was developed. The interface could transfer droplets from segmented phase to aqueous phase with high reliability and high controllability by coupling with a back pressure regulator. The flow injection mode was adopted to introduce the transferred droplets to the ESI emitter for minimizing the cross-contamination between droplets and achieving droplet matrix modification. The system performance was evaluated using angiotensin as a model sample, and high sensitivity (<1 μM) and a good reproducibility of 5.2% RSD (n = 7) were obtained. The present device was further applied in the online monitoring of droplet-based microreaction for alkylation of peptide.
本文描述了一种简单、鲁棒、集成的基于微芯片的液滴分析系统,该系统具有电喷雾电离-质谱(ESI-MS)检测功能。该微芯片集成了多个模块,包括液滴发生器、液滴提取接口和整体式 ESI 发射器。本文还开发了一种基于亲水舌结构的新型液滴提取接口。该接口通过与背压调节器耦合,可以高可靠性和高可控性地将液滴从分段相转移到水相。采用流动注射模式将转移的液滴引入 ESI 发射器,以最大程度地减少液滴之间的交叉污染并实现液滴基质修饰。本文使用血管紧张素作为模型样品评估了该系统的性能,获得了<1 μM 的高灵敏度和 5.2%RSD(n=7)的良好重现性。该装置还进一步应用于基于液滴的微反应的在线监测,用于肽的烷基化反应。