Abstract

OBJECTIVE

To compare the first throw tension holding properties of twisted versus straight first throws in two commonly used Oculoplastic braided absorbable sutures.

DESIGN

An in-vitro experimental model.

METHODS

Variable loads were applied to the first double throw of a surgical knot - either in straight-line configuration or twisting the knot using both 6/0 Polyglycolic acid (Dexon S) and 6/0 Polyglactin 910 (Coated Vicryl). Each suture was tested to the point of knot slipping and the critical tension recorded. Two variations of the experiment were undertaken: Experiment 1 - two metal loops were brought together by the test suture, experiment 2 - two strips of tissue (Permacol - cross-linked porcine dermal collagen) were brought together by the test suture.

RESULTS

Experiment 1 straight: Polyglycolic acid 12.2g (11-13.5), Polyglactin-910 2.5 g (2.5- no range). Experiment 1 twisted: Polyglycolic acid 13.33 g (10-15), Polyglactin 910 3 g (2-5). Experiment 2 straight: Polyglycolic acid 33g (30-35), Polyglactin 910 25g (25 - no range). Experiment 2 twisted: Polyglycolic acid 35 (30-40), Polyglactin 910 25g (20-30).

CONCLUSIONS

Twisting the suture adds only a modest increase in first throw knot security. Polyglycolic acid (Dexon S) braided absorbable suture has significantly better first throw knot security when compared with Polyglactin-910 (coated Vicryl). This is an important property when suturing tissues under tension as it minimises slippage before the locking throw is tied.

摘要

目的

比较两种常用的眼科整形编织可吸收缝线中,扭结与直结的首次打结张力保持特性。

设计

体外实验模型。

方法

对手术结的第一个双结施加可变负荷——结呈直线构型或使用6/0聚乙醇酸(Dexon S)和6/0聚乳酸910(涂层薇乔)扭结。每种缝线均测试至结滑动点,并记录临界张力。进行了两种实验变体:实验1——用测试缝线将两个金属环拉拢,实验2——用测试缝线将两条组织条(Permacol——交联猪真皮胶原蛋白)拉拢。

结果

实验1直结:聚乙醇酸12.2克(11 - 13.5),聚乳酸910 2.5克(2.5 - 无范围)。实验1扭结:聚乙醇酸13.33克(10 - 15),聚乳酸910 3克(2 - 5)。实验2直结:聚乙醇酸33克(30 - 35),聚乳酸910 25克(25 - 无范围)。实验2扭结:聚乙醇酸35(30 - 40),聚乳酸910 25克(20 - 30)。

结论

扭结仅适度增加首次打结的安全性。与聚乳酸910(涂层薇乔)相比,聚乙醇酸(Dexon S)编织可吸收缝线的首次打结安全性显著更高。在张力下缝合组织时,这是一项重要特性,因为它可在打锁定结之前将滑动降至最低。

相似文献

6
First throw tension versus coatings: a solution offered.
Clin Exp Ophthalmol. 2006 Nov;34(8):814; author reply 815. doi: 10.1111/j.1442-9071.2006.01379.x.
9
Tensile strength of surgical knots performed with the da Vinci surgical robot.
J Minim Invasive Gynecol. 2010 May-Jun;17(3):365-70. doi: 10.1016/j.jmig.2010.01.005. Epub 2010 Mar 15.
10
Mechanical properties of coated absorbable multifilament suture materials.
Obstet Gynecol. 1986 May;67(5):737-40. doi: 10.1097/00006250-198605000-00025.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验