磁共振成像与计算机断层扫描在保乳治疗中对乳腺腺体型靶区(临床靶区乳房)勾画的对比:一项探索性研究。

Magnetic resonance imaging- versus computed tomography-based target volume delineation of the glandular breast tissue (clinical target volume breast) in breast-conserving therapy: an exploratory study.

机构信息

Radiotherapy Center West, The Hague, The Netherlands.

出版信息

Int J Radiat Oncol Biol Phys. 2011 Nov 1;81(3):804-11. doi: 10.1016/j.ijrobp.2010.07.004. Epub 2010 Sep 16.

Abstract

PURPOSE

To examine MRI and CT for glandular breast tissue (GBT) volume delineation and to assess interobserver variability.

METHODS AND MATERIALS

Fifteen breast cancer patients underwent a planning CT and MRI, consecutively, in the treatment position. Four observers (two radiation oncologists and two radiologists) delineated the GBT according to the CT and separately to the MR images. Volumes, centers of mass, maximum extensions with standard deviations (SD), and interobserver variability were quantified. Observers viewed delineation differences between MRI and CT and delineation differences among observers.

RESULTS

In cranio-lateral and cranio-medial directions, GBT volumes were delineated larger using MRI when compared with those delineated with CT. Center of mass on MRI shifted a mean (SD) 17% (4%) into the cranial direction and a mean 3% (4%) into the dorsal direction when compared with that on the planning CT. Only small variations between observers were noted. The GBT volumes were approximately 4% larger on MRI (mean [SD] ratio MRI to CT GBT volumes, 1.04 [0.06]). Findings were concordant with viewed MRI and CT images and contours. Conformity indices were only slightly different; mean conformity index was 77% (3%) for MRI and 79% (4%) for CT. Delineation differences arising from personal preferences remained recognizable irrespective of the imaging modality used.

CONCLUSIONS

Contoured GBT extends substantially further into the cranio-lateral and cranio-medial directions on MRI when compared with CT. Interobserver variability is comparable for both imaging modalities. Observers should be aware of existing personal delineation preferences. Institutions are recommended to review and discuss target volume delineations and to design supplementary guidelines if necessary.

摘要

目的

研究 MRI 和 CT 用于乳腺实质(GBT)体积勾画,并评估观察者间的变异性。

方法和材料

15 例乳腺癌患者在治疗体位下连续进行计划 CT 和 MRI 检查。4 名观察者(2 名放射肿瘤学家和 2 名放射科医生)根据 CT 和 MRI 图像分别对 GBT 进行勾画。量化了体积、质心、最大扩展及其标准差(SD)和观察者间的变异性。观察者观察了 MRI 和 CT 之间以及观察者之间的勾画差异。

结果

在颅侧-外侧和颅侧-内侧方向,与 CT 相比,MRI 勾画的 GBT 体积更大。与计划 CT 相比,MRI 上的质心向颅侧平均(SD)移动 17%(4%),向背侧平均移动 3%(4%)。仅观察到观察者之间的微小变化。MRI 上的 GBT 体积大约大 4%(MRI 与 CT 上 GBT 体积的平均[SD]比值,1.04[0.06])。这些发现与观察到的 MRI 和 CT 图像和轮廓一致。一致性指数仅略有不同;MRI 的平均一致性指数为 77%(3%),CT 为 79%(4%)。无论使用哪种成像方式,由于个人偏好而产生的勾画差异仍然是可识别的。

结论

与 CT 相比,MRI 上的 GBT 在颅侧-外侧和颅侧-内侧方向上延伸得更远。两种成像方式的观察者间变异性相当。观察者应该意识到现有的个人勾画偏好。建议机构审查和讨论靶区勾画,并在必要时设计补充指南。