Department of Population Health Sciences, University of Wisconsin, Madison (MP, DGF)
Center for Urban Population Health, Milwaukee, Wisconsin (H-YC)
Med Decis Making. 2011 Mar-Apr;31(2):260-9. doi: 10.1177/0272989X10380925. Epub 2010 Oct 8.
Standard errors of measurement (SEMs) of health-related quality of life (HRQoL) indexes are not well characterized. SEM is needed to estimate responsiveness statistics, and is a component of reliability.
To estimate the SEM of 5 HRQoL indexes.
The National Health Measurement Study (NHMS) was a population-based survey. The Clinical Outcomes and Measurement of Health Study (COMHS) provided repeated measures.
A total of 3844 randomly selected adults from the noninstitutionalized population aged 35 to 89 y in the contiguous United States and 265 cataract patients.
The SF6-36v2™, QWB-SA, EQ-5D, HUI2, and HUI3 were included. An item-response theory approach captured joint variation in indexes into a composite construct of health (theta). The authors estimated 1) the test-retest standard deviation (SEM-TR) from COMHS, 2) the structural standard deviation (SEM-S) around theta from NHMS, and 3) reliability coefficients.
SEM-TR was 0.068 (SF-6D), 0.087 (QWB-SA), 0.093 (EQ-5D), 0.100 (HUI2), and 0.134 (HUI3), whereas SEM-S was 0.071, 0.094, 0.084, 0.074, and 0.117, respectively. These yield reliability coefficients 0.66 (COMHS) and 0.71 (NHMS) for SF-6D, 0.59 and 0.64 for QWB-SA, 0.61 and 0.70 for EQ-5D, 0.64 and 0.80 for HUI2, and 0.75 and 0.77 for HUI3, respectively. The SEM varied across levels of health, especially for HUI2, HUI3, and EQ-5D, and was influenced by ceiling effects. Limitations. Repeated measures were 5 mo apart, and estimated theta contained measurement error.
The 2 types of SEM are similar and substantial for all the indexes and vary across health.
健康相关生活质量(HRQoL)指标的测量标准误差(SEM)尚未得到很好的描述。SEM 用于估计反应性统计数据,是可靠性的组成部分。
估计 5 个 HRQoL 指标的 SEM。
国家健康测量研究(NHMS)是一项基于人群的调查。临床结果和健康测量研究(COMHS)提供了重复测量。
来自美国大陆 35 至 89 岁的非机构化人群中随机选择的 3844 名成年人和 265 名白内障患者。
包括 SF6-36v2™、QWB-SA、EQ-5D、HUI2 和 HUI3。一种基于项目反应理论的方法将指标的联合变化纳入健康(theta)的综合结构。作者估计了 1)来自 COMHS 的测试-重测标准偏差(SEM-TR),2)来自 NHMS 的围绕 theta 的结构标准偏差(SEM-S),3)可靠性系数。
SF-6D、QWB-SA、EQ-5D、HUI2 和 HUI3 的 SEM-TR 分别为 0.068、0.087、0.093、0.100 和 0.134,而 SEM-S 分别为 0.071、0.094、0.084、0.074 和 0.117。这分别产生了 SF-6D 的可靠性系数 0.66(COMHS)和 0.71(NHMS)、QWB-SA 的 0.59 和 0.64、EQ-5D 的 0.61 和 0.70、HUI2 的 0.64 和 0.80,以及 HUI3 的 0.75 和 0.77。SEM 因健康水平而异,尤其是 HUI2、HUI3 和 EQ-5D,且受到天花板效应的影响。局限性:重复测量相隔 5 个月,估计的 theta 包含测量误差。
2 种 SEM 对于所有指标都相似且较大,且因健康状况而异。