• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Noncontact and noninvasive microwave biological measurements].

作者信息

Misawa T, Kutsumi Y, Tada H, Kim S S, Nakai T, Miyabo S, Hamada T, Arai I, Suzuki T

机构信息

Third Department of Internal Medicine, Fukui Medical School Matsuoka-cho.

出版信息

J Cardiol. 1990;20(1):209-16.

PMID:2093754
Abstract

Without contact probes, the signals of small human body surface movements were obtained with microwave Doppler sensors using a two-phase interferometric method. The signals were then compared with mechanocardiographic records routinely obtained by contact transducers. Furthermore, this system was applied to patients wearing clothes. The study subjects consisted of 20 cardiac patients and 10 normal controls. 1. The microwave signals obtained in the cervical and precordial regions were similar to those of the mechanocardiographic recordings, such as the carotid pulse and jugular venous pulse tracings and the apexcardiogram. There was a significant correlation between left ventricular ejection time (LVET) obtained by microwave Doppler sensors and that by the carotid pulse tracing (r = 0.95). 2. The signals of the microwave Doppler sensor were obtained from the patients wearing clothes. The heart beat components were distinguished from respiratory motion and patients' movements using band-pass filters. These results suggest that this method is capable of evaluating cardiac function noninvasively and thus has a distinct advantage in the field of non-contact measurements.

摘要

相似文献

1
[Noncontact and noninvasive microwave biological measurements].
J Cardiol. 1990;20(1):209-16.
2
Doppler microwave. A clinical assessment of its efficacy as an arterial pulse sensing technique.
Invest Radiol. 1987 Jul;22(7):569-73.
3
[Noncontact noninvasive measurement of mechanocardiography and pulse wave velocity by microwave Doppler sensor].
Kokyu To Junkan. 1990 Oct;38(10):995-9.
4
Non-contact cardiac monitoring from carotid artery using optical vibrocardiography.
Med Eng Phys. 2008 May;30(4):490-7. doi: 10.1016/j.medengphy.2007.05.008. Epub 2007 Jul 10.
5
Development of a noncontact and long-term respiration monitoring system using microwave radar for hibernating black bear.利用微波雷达开发一种用于冬眠黑熊的非接触式长期呼吸监测系统。
Zoo Biol. 2009 May;28(3):259-70. doi: 10.1002/zoo.20229.
6
Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function.左心室每搏输出量变异度在评估心功能减退患者液体反应性中的应用价值
Crit Care Med. 2003 May;31(5):1399-404. doi: 10.1097/01.CCM.0000059442.37548.E1.
7
Comparative measurements of left ventricular ejection time by mechano-, echo- and electrical impedance cardiography.通过机械、超声和电阻抗心动图对左心室射血时间进行的对比测量。
Arzneimittelforschung. 1985;35(10):1582-6.
8
Correlations between ejection times measured from the carotid pulse contour and the impedance cardiogram.从颈动脉脉搏轮廓测量的射血时间与阻抗心动图之间的相关性。
Aviat Space Environ Med. 1983 Oct;54(10):894-7.
9
[A new approach to the left ventricular ejection time by systolic time intervals measurement with carotid arterial Doppler. Statistical study of correlation in one hundred and thirteen cases (author's transl)].
Sem Hop. 1981;57(25-28):1206-8.
10
Modelflow: a new method for noninvasive assessment of cardiac output in pregnant women.模型血流动力学:一种无创评估孕妇心输出量的新方法。
Am J Obstet Gynecol. 2007 Mar;196(3):235.e1-8. doi: 10.1016/j.ajog.2006.10.896.