Keller J C, Draughn R A, Wightman J P, Dougherty W J, Meletiou S D
College of Dentistry, University of Iowa, Iowa City.
Int J Oral Maxillofac Implants. 1990 Winter;5(4):360-7.
Surface analysis techniques and in vitro biologic assays were used to characterize sterilized commercially pure titanium surfaces. Significant surface alterations were observed following sterilization treatments. These alterations led to decreased fibroblast cell attachment and altered cellular spreading phenomena compared to nonsterilized control surfaces.
采用表面分析技术和体外生物学检测方法对商业纯钛灭菌表面进行表征。灭菌处理后观察到显著的表面变化。与未灭菌的对照表面相比,这些变化导致成纤维细胞附着减少,并改变了细胞铺展现象。