Wu Z C, Goodall D M, Lloyd D K
Chemistry Department, University of York, Heslington, UK.
J Pharm Biomed Anal. 1990;8(4):357-64. doi: 10.1016/0731-7085(90)80050-y.
A reversed-phase high-performance liquid chromatography (HPLC) method with dual optical rotation/UV absorbance detection has been developed for the determination of enantiomeric purity of ephedrine hydrochloride and pseudoephedrine hydrochloride using an achiral column. The method gave a correlation coefficient of 0.9997 for the plot of log(optical rotation response) versus log (concentration) over the range of 0.06-10 mg ml(-1) of (+)-ephedrine hydrochloride (20 microliters injection). The limit of detection was 1.0 micrograms. Enantiomeric purity is shown to be most readily determined by measuring optical rotation, alpha, and absorbance, A, responses for standard and unknown samples, and using the equation (alpha/A)u/(alpha/A)s = (2xu - 1)/(2xs - 1), where x is the mole fraction of one of the enantiomers and subscripts s and u refer to standard and unknown, respectively. In blind trials using unknown mixtures of (+)- and (+/-)-ephedrine hydrochloride and a (+)-ephedrine hydrochloride standard, enantiomeric purities were determined to +/- 0.4% (95% confidence level) with five or six replicate 50 micrograms injections. The method has also been applied to the determination of the enantiomer mole fraction of (+)-pseudoephedrine hydrochloride in a cough linctus, giving xu = 0.99 +/- 0.01 with seven replicate injections of 20-fold diluted linctus samples containing 7.5 micrograms of the chiral compound being assayed. Unlike conventional polarimetry, the method does not require chemically-pure samples and can be orders of magnitude more economical in material.
已开发出一种具有双旋光/紫外吸光度检测功能的反相高效液相色谱(HPLC)方法,用于使用非手性柱测定盐酸麻黄碱和盐酸伪麻黄碱的对映体纯度。在0.06 - 10 mg ml⁻¹的(+)-盐酸麻黄碱(进样20微升)范围内,log(旋光响应)对log(浓度)的曲线的相关系数为0.9997。检测限为1.0微克。对映体纯度最容易通过测量标准样品和未知样品的旋光度α和吸光度A响应,并使用方程(α/A)u/(α/A)s = (2xu - 1)/(2xs - 1)来确定,其中x是对映体之一的摩尔分数,下标s和u分别指标准样品和未知样品。在使用(+)-和(+/-)-盐酸麻黄碱的未知混合物以及(+)-盐酸麻黄碱标准品的盲法试验中,通过五次或六次重复进样50微克,对映体纯度测定的置信水平为±0.4%(95%置信水平)。该方法还已应用于止咳糖浆中(+)-盐酸伪麻黄碱对映体摩尔分数的测定,对含7.5微克被测手性化合物的止咳糖浆样品进行20倍稀释后,七次重复进样得到xu = 0.99 ± 0.01。与传统旋光法不同,该方法不需要化学纯样品,且在材料上可节省几个数量级的成本。