J Vet Intern Med. 2010 Nov-Dec;24(6):1290-7. doi: 10.1111/j.1939-1676.2010.0609.x. Epub 2010 Oct 12.
Contrast-enhanced ultrasonography with perflubutane microbubbles improves the diagnostic accuracy to differentiate benign and malignant focal liver lesions in dogs.
Perflubutane microbubbles-enhanced ultrasonography is useful for differentiation of benign from malignant focal splenic lesions in dogs.
Twenty-nine clinical dogs with single or multiple focal splenic lesions detected by conventional ultrasonography.
Prospective clinical observational study. Perflubutane microbubbles-enhanced ultrasonography was performed in 29 dogs with focal splenic lesions. Qualitative assessment of the enhancement pattern was performed in the early vascular, late vascular, and parenchymal phases.
In the early vascular phase, a hypoechoic pattern was significantly associated with malignancy (P=.02) with sensitivity of 38% (95% confidence interval [CI], 25-38%) and specificity of 100% (95% CI, 84-100%). In the late vascular phase, a hypoechoic pattern was significantly associated with malignancy (P=.001) with sensitivity of 81% (95% CI, 66-90%) and specificity of 85% (95% CI, 65-95%). There was no significant difference between malignant and benign lesions during the parenchymal phase.
Hypoechoic splenic nodules in the early and late vascular phases with perflubutane microbubbles-enhanced ultrasonography are strongly suggestive of malignancy in dogs.
使用全氟丁烷微泡进行超声造影可以提高鉴别犬良性和恶性局灶性肝脏病变的诊断准确性。
全氟丁烷微泡增强超声对鉴别犬良性和恶性局灶性脾脏病变是有用的。
通过常规超声检查发现的 29 只具有单个或多个局灶性脾脏病变的临床犬。
前瞻性临床观察性研究。对 29 只具有局灶性脾脏病变的犬进行全氟丁烷微泡增强超声检查。在早期血管期、晚期血管期和实质期对增强模式进行定性评估。
在早期血管期,低回声模式与恶性肿瘤显著相关(P=.02),敏感性为 38%(95%可信区间[CI],25-38%),特异性为 100%(95% CI,84-100%)。在晚期血管期,低回声模式与恶性肿瘤显著相关(P=.001),敏感性为 81%(95% CI,66-90%),特异性为 85%(95% CI,65-95%)。在实质期,恶性和良性病变之间没有显著差异。
使用全氟丁烷微泡增强超声检查,在早期和晚期血管期出现低回声脾脏结节强烈提示犬存在恶性肿瘤。