Six workers exposed as bystanders to heated triglycidyl isocyanurate (TGIC) developed occupational asthma confirmed by serial peak expiratory flow measurement and Oasys analysis. Specific inhalation challenge testing resulted in late or dual asthmatic reactions to heated TGIC in four of four tested and was negative in three control asthmatics. One worker tested only with unheated TGIC had a negative specific challenge test. Heated TGIC can cause occupational asthma from bystander exposure.
六名工人作为旁观者暴露于加热的三缩水甘油异氰尿酸酯(TGIC)中,通过连续峰流速测量和 Oasys 分析证实患有职业性哮喘。对四名测试者中的四名进行了加热 TGIC 的特异性吸入挑战测试,结果显示出现迟发性或双重哮喘反应,而在三名对照哮喘患者中则为阴性。仅用未加热的 TGIC 进行测试的一名工人的特异性挑战测试为阴性。加热的 TGIC 可导致旁观者暴露引起职业性哮喘。