Suppr超能文献

术后腕关节内桡骨远端骨折的 X 线和多层螺旋 CT 比较评估。

Comparative evaluation of postreduction intra-articular distal radial fractures by radiographs and multidetector computed tomography.

机构信息

Department of Orthopaedic Surgery, Maulana Azad Medical College and Lok Nayak Hospital, New Delhi 110002, India.

出版信息

J Bone Joint Surg Am. 2010 Nov 3;92(15):2523-32. doi: 10.2106/JBJS.I.01617.

Abstract

BACKGROUND

Computed tomography can be an adjunct to radiographs when evaluating intra-articular fractures of the distal part of the radius. Acute-phase multidetector computed tomography has better temporal, spatial, and contrast resolution than a conventional scanner has. The aim of this study was to determine prospectively whether the addition of a multidetector computed tomography scan (with various reconstructions) results in changes in the evaluation of intra-articular distal radial fractures and thus changes in the plans for further management.

METHODS

Radiographs and multidetector computed tomography scans were compared prospectively in the evaluation of 117 patients (120 wrists) with acute intra-articular distal radial fractures. The parameters that were measured included the ability to detect intra-articular step and gap displacements, central articular depression, coronal plane fracture, the number of articular fragments, comminution, and associated injuries in the wrist region (carpal bone fractures, distal radioulnar joint disruption, and ulnar styloid fracture).

RESULTS

The average measurements for intra-articular step and gap were 0.4 mm and 0.9 mm, respectively, on post-reduction radiographs and 1.3 mm and 2.4 mm, respectively, on sagittal multidetector computed tomography images (p < 0.0001 for each). Central articular depression was found in twenty-one wrists (18% of the total) on radiographs, but on multidetector computed tomography it was found to be present in seventy-four wrists (62% of the total) (p < 0.0001). Twenty-six radiographically occult injuries in the wrist region, including six scaphoid fractures, were detected with the help of multidetector computed tomography. Overall, the recommended treatment plan changed in 23% of the cases when the evaluation included multidetector computed tomography images in addition to conventional radiographs. Interobserver and intraobserver agreements were significantly increased when radiographs and multidetector computed tomography images both were available for evaluation (κ = 0.73 and 0.91, respectively) as compared with interobserver and intraobserver agreement with radiographs alone (κ = 0.43 and 0.69, respectively).

CONCLUSIONS

Multidetector computed tomography provides more accurate information regarding the anatomy of intra-articular distal radial fractures than radiography provides. The addition of multidetector computed tomography to plain films frequently changes the therapeutic recommendations for such cases.

摘要

背景

在评估桡骨远端关节内骨折时,计算机断层扫描可以作为 X 光片的辅助手段。与传统扫描仪相比,急性多排 CT 具有更好的时间、空间和对比分辨率。本研究的目的是前瞻性地确定多排 CT 扫描(具有各种重建)是否会改变对关节内桡骨远端骨折的评估,从而改变进一步治疗的计划。

方法

前瞻性比较 117 例(120 腕)急性关节内桡骨远端骨折患者的 X 光片和多排 CT 扫描。测量的参数包括检测关节内台阶和间隙移位、中央关节凹陷、冠状面骨折、关节内碎片数量、粉碎程度以及腕部(腕骨骨折、桡尺远侧关节脱位和尺骨茎突骨折)相关损伤的能力。

结果

复位后 X 光片上关节内台阶和间隙的平均测量值分别为 0.4mm 和 0.9mm,矢状多排 CT 图像上分别为 1.3mm 和 2.4mm(p<0.0001)。21 个腕关节(占总数的 18%)在 X 光片上发现中央关节凹陷,而在多排 CT 上发现 74 个腕关节(占总数的 62%)存在中央关节凹陷(p<0.0001)。26 例腕部隐匿性损伤,包括 6 例舟状骨骨折,借助多排 CT 发现。总体而言,当评估包括常规 X 光片和多排 CT 图像时,23%的病例推荐的治疗计划发生变化。与仅使用 X 光片时的观察者间和观察者内一致性(κ=0.43 和 0.69)相比,当同时使用 X 光片和多排 CT 图像时,观察者间和观察者内的一致性显著提高(κ=0.73 和 0.91)。

结论

与 X 光片相比,多排 CT 提供了更准确的关节内桡骨远端骨折解剖信息。多排 CT 与 X 光片联合应用常改变此类病例的治疗建议。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验