Suppr超能文献

健康志愿者皮下注射用一次性自动注射器的性能、安全性、受试者接受度及依从性评估。

Evaluation of performance, safety, subject acceptance, and compliance of a disposable autoinjector for subcutaneous injections in healthy volunteers.

作者信息

Berteau Cecile, Schwarzenbach Florence, Donazzolo Yves, Latreille Mathilde, Berube Julie, Abry Herve, Cotten Joël, Feger Celine, Laurent Philippe E

机构信息

BD Medical Pharmaceutical Systems, Le-Pont-de-Claix.

出版信息

Patient Prefer Adherence. 2010 Oct 5;4:379-88. doi: 10.2147/ppa.s13132.

Abstract

OBJECTIVE

A disposable autoinjector was developed for subcutaneous (SC) self-injection by patients with chronic diseases. To verify its performance and evaluate its acceptance, a clinical study was conducted in healthy volunteers, comparing SC injections performed by subjects using the autoinjector with SC injections performed by nurses using a syringe.

METHODS

This was a randomized, single-center, crossover study comparing SC self-injection using an autoinjector with SC nurse-administered injection using a syringe. Two volumes (0.2 mL and 1 mL) were injected into healthy volunteers. Study objectives included assessment of the accuracy and consistency of the volume injected by the injection systems, and skin reaction and pain associated with the injection. The fluid depot in the SC tissue layer was evaluated by ultrasound. Subject acceptance was evaluated using questionnaires on attitudes and emotions towards the injection technique, and challenged by seeking the subjects' preferred system for a final study injection or future treatment.

RESULTS

A total of 960 injections (480 with autoinjector, 480 with syringe) were performed in 40 subjects. There were no significant differences in mean fluid leakage and injected volumes between the systems. Pain associated with the injection was significantly lower with the auto-injector than with the syringe. Local skin reaction at the injection site was overall satisfactory. Injections were appropriately performed by all subjects. At study end, all 40 subjects preferred the autoinjector for a final study injection and for future treatment.

CONCLUSION

This study indicated that the autoinjector used by the subject was similar to a syringe used by a nurse in terms of performance and safety in administering the injections, and better in terms of pain, overall acceptance, and preference.

摘要

目的

为慢性病患者开发了一种用于皮下(SC)自我注射的一次性自动注射器。为验证其性能并评估其可接受性,在健康志愿者中进行了一项临床研究,比较受试者使用自动注射器进行的皮下注射与护士使用注射器进行的皮下注射。

方法

这是一项随机、单中心、交叉研究,比较使用自动注射器进行的皮下自我注射与护士使用注射器进行的皮下注射。向健康志愿者注射两种剂量(0.2毫升和1毫升)。研究目标包括评估注射系统注射剂量的准确性和一致性,以及与注射相关的皮肤反应和疼痛。通过超声评估皮下组织层中的液体积聚。使用关于对注射技术的态度和情绪的问卷评估受试者的接受度,并通过询问受试者最终研究注射或未来治疗的首选系统来进行挑战。

结果

40名受试者共进行了960次注射(480次使用自动注射器,480次使用注射器)。两种系统之间的平均液体渗漏和注射剂量没有显著差异。自动注射器注射相关的疼痛明显低于注射器。注射部位的局部皮肤反应总体令人满意。所有受试者的注射操作都正确。在研究结束时,所有40名受试者在最终研究注射和未来治疗中都更喜欢自动注射器。

结论

本研究表明,受试者使用的自动注射器在注射给药的性能和安全性方面与护士使用的注射器相似,在疼痛、总体接受度和偏好方面更好。