Suppr超能文献

血清冻干对载脂蛋白A-I和B测量的影响。

Effects of lyophilization of serum on the measurement of apolipoproteins A-I and B.

作者信息

Marcovina S M, Adolphson J L, Parlavecchia M, Albers J J

机构信息

Northwest Lipid Research Center, Harborview Medical Center, Seattle, WA 98104-2499.

出版信息

Clin Chem. 1990 Feb;36(2):366-9.

PMID:2105863
Abstract

A common accuracy-based standardization program is indispensable for establishing reference intervals for the clinical use of apolipoproteins. The development and distribution of reference materials and quality-control materials that do not exhibit matrix effects between methods is essential to the standardization process. We examined the suitability of lyophilized material as a common reference material for the measurement of apolipoproteins A-I and B. We determined values for apolipoproteins A-I and B in frozen and lyophilized serum pools, using different immunochemical approaches. We found little or no differences in apolipoprotein A-I values between frozen and lyophilized pools as determined by the different methods. In contrast, values for apolipoprotein B in lyophilized samples were consistently lower than those obtained for frozen samples. After adjusting for the effect of dilution due to reconstitution, the difference in the apolipoprotein B values for lyophilized as compared with frozen samples ranged from -26% to 4%, depending upon the assay method. Evidently, serum pools in lyophilized from are not a suitable matrix for reference materials for apolipoprotein B measurements but can be used for apolipoprotein A-I measurements.

摘要

一个基于准确性的通用标准化程序对于建立载脂蛋白临床应用的参考区间是必不可少的。开发和分发在不同方法间不表现出基质效应的参考物质和质量控制物质对于标准化过程至关重要。我们检验了冻干物质作为载脂蛋白A-I和B测量通用参考物质的适用性。我们使用不同的免疫化学方法测定了冷冻和冻干血清库中载脂蛋白A-I和B的值。我们发现,不同方法测定的冷冻和冻干库中载脂蛋白A-I值几乎没有差异。相比之下,冻干样品中载脂蛋白B的值始终低于冷冻样品中的值。在调整因复溶导致的稀释效应后,冻干样品与冷冻样品相比,载脂蛋白B值的差异在-26%至4%之间,具体取决于检测方法。显然,冻干血清库不是载脂蛋白B测量参考物质的合适基质,但可用于载脂蛋白A-I测量。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验