The aim of this study was to investigate the repeatability of manual measurements of choroidal thickness in healthy subjects imaged on spectral domain optical coherence tomography (OCT) using the enhanced depth imaging (EDI) technique.
Fifty consecutive, healthy, young, adult volunteers with no known eye disease were enrolled prospectively. Two good-quality horizontal and vertical line scans through the fovea were obtained for each eye. Using the manual calipers provided by the software of the proprietary device, two experienced OCT readers measured the subfoveal choroidal thickness (SFCT) of the horizontal and vertical line scans for all eyes. The readers were masked to each other's readings. Intraobserver, interobserver, and intrasession coefficients of repeatability (CRs) were calculated.
Mean (standard deviation [SD]) age of the study subjects was 38 (5) years (range, 30-49 years). Mean (SD) subfoveal choroidal thickness was 332 (90) μm (right eyes) and 332 (91) μm (left eyes). Intraobserver CR was approximately 23 (95% confidence interval [CI], 19-26) μm, whereas interobserver and intrasession CRs were greater at 32 (95% CI, 30-34) and 34 (95% CI, 32-36) μm, respectively. There was no significant difference in SFCT between all pairs of SFCT measurements except for the two intrasession vertical line scans.
A change of >32 μm was likely to exceed interobserver variability in SFCT. Future studies are required to estimate the repeatability of SFCT measurements in patients with chorioretinal pathology.
本研究旨在探讨应用增强深度成像(EDI)技术的谱域光相干断层扫描(OCT)对健康受试者脉络膜厚度进行手动测量的重复性。
前瞻性纳入 50 例连续的、无已知眼部疾病的健康年轻成年志愿者。每只眼均获得 2 条质量良好的水平和垂直黄斑区扫描线。使用专有设备软件提供的手动卡尺,由 2 名有经验的 OCT 读取者对所有眼的水平和垂直扫描线的黄斑下脉络膜厚度(SFCT)进行测量。读取者彼此之间的读数是盲法的。计算了观察者内、观察者间和日内的重复性系数(CR)。
研究对象的平均(标准差[SD])年龄为 38(5)岁(范围,30-49 岁)。平均(SD)SFCT 为 332(90)μm(右眼)和 332(91)μm(左眼)。观察者内 CR 约为 23(95%置信区间[CI],19-26)μm,而观察者间和日内 CR 则分别为 32(95% CI,30-34)和 34(95% CI,32-36)μm,更大。除了两条日内垂直扫描线外,所有 SFCT 测量值之间的 SFCT 无显著差异。
SFCT 的变化>32 μm 可能超过观察者间的变异性。未来的研究需要估计在有脉络膜视网膜病变的患者中 SFCT 测量的重复性。