Suppr超能文献

Monitoring microemboli during cardiopulmonary bypass with the EDAC quantifier.

作者信息

Lynch John E, Wells Christopher, Akers Tom, Frantz Paul, Garrett Donna, Scott M Lance, Williamson Lisa, Agnew Barbara, Lynch John K

机构信息

Luna Innovations Incorporated, Hampton, Virginia, USA.

出版信息

J Extra Corpor Technol. 2010 Sep;42(3):212-8.

Abstract

Gaseous emboli may be introduced into the bypass circuit both from the surgical field and during perfusionist interventions. While circuits provide good protection against massive air embolism, they do not remove gaseous microemboli (GME) from the bypass circuit. The purpose of this preliminary study is to assess the incidence of GME during bypass surgery and determine if increased GME counts were associated with specific events during bypass surgery. In 30 cases divided between 15 coronary artery bypass grafts and 15 valve repairs, GME were counted and sizedt the three locations on the bypass circuit using the EDAC" Quantifier (Luna Innovations, Roanoke, VA). A mean of 45,276 GME were detected after the arterial line filter during these 30 cases, with significantly more detected (p = .04) post filter during valve cases (mean = 72,137 +/- 22,113) than coronary artery bypass graft cases (mean = 18,416 +/- 7831). GME detected post filter were significantly correlated in time with counts detected in the venous line (p < .001). Specific events associated with high counts included the initiation of cardiopulmonary bypass, heart manipulations, insertion and removal of clamps, and the administration of drugs. Global factors associated with increased counts post filter included higher venous line counts and higher post reservoir/bubble trap counts. The mean number of microemboli detected during bypass surgery was much higher than reported in other studies of emboli incidence, most likely due to the increased sensitivity of the EDAC Quantifier compared to other detection modalities. The results furthermore suggest the need for further study of the clinical significance of these microemboli and what practices may be used to reduce GME incidence. Increased in vitro testing of the air handling capability of different circuit designs, along with more clinical studies assessing best clinical practices for reducing GME activity, is recommended.

摘要

相似文献

本文引用的文献

2
7
Bubbles and bypass: an update.气泡与分流:最新进展
Perfusion. 2004;19 Suppl 1:S49-55. doi: 10.1191/0267659104pf720oa.
9
The pathophysiology of cerebral arterial gas embolism.
J Extra Corpor Technol. 2002 Mar;34(1):18-23.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验