Periodontal disease in cats is highly prevalent, and its aetiology is associated to bacteria located in the subgingival microbiota, being Porphyromonas sp. the most prevalent genus. The conventional technique to sample the subgingival microbiota is the use of cotton swabs over the mucosa and teeth; however the use of subgingival paper points could improve the bacterial recovery.
The objective was to compare two microbial sampling approaches for the evaluation of the periodontal disease-associated microflora in cats.
The study was designed as a pilot study. Ten cats were clinically evaluated and sampled under sedation. Subgingival pooled samples were collected from four sites. In parallel, samples were obtained with a cotton swab, by striking over the gingival margin and surface of the upper right canine. Samples were cultured on blood agar (aerobic and anaerobic incubation), Dentaid-1 (for Aggregatibacter actinomycetemcomitans and enterics), and a specific medium for Bartonella henselae.
For total anaerobic counts, paper point samples (6.59 ± 0.5) demonstrated significantly higher counts (p=0.03) than cotton swab samples (5.54 ± 1.1). Moreover, the use of paper points increased the frequency detection of most pathogens thus reducing false negatives for Porphyromonas gulae (100% with paper points samples and 80% with cotton swab samples).
Significant higher recoveries of anaerobic bacteria and more frequent detection of putative periodontal pathogens was observed when microbiological sampling was performed with paper points, in cats with periodontal disease.
猫牙周病的发病率很高,其病因与龈下微生物群中的细菌有关,其中普氏菌属最为常见。采集龈下微生物群的常规技术是使用棉拭子擦拭黏膜和牙齿;然而,使用龈下纸尖可以提高细菌回收率。
旨在比较两种微生物采样方法,以评估猫牙周病相关微生物群。
该研究设计为一项初步研究。10 只猫在镇静下进行临床评估和采样。从四个部位采集龈下混合样本。同时,用棉拭子通过敲击牙龈边缘和右上犬齿表面采集样本。样本接种于血琼脂(需有氧和厌氧孵育)、Dentaid-1(用于检测伴放线放线杆菌和肠球菌)和用于巴尔通体亨氏亚种的特定培养基上。
对于总厌氧菌计数,纸尖样本(6.59±0.5)的计数明显高于棉拭子样本(5.54±1.1)(p=0.03)。此外,使用纸尖增加了大多数病原体的检测频率,从而减少了普氏菌属(用纸尖样本检测时为 100%,用棉拭子样本检测时为 80%)的假阴性率。
在患有牙周病的猫中,使用纸尖进行微生物采样时,可明显提高厌氧菌的回收率,并更频繁地检测到潜在的牙周病病原体。