Optimal double screw configuration for subtalar arthrodesis: a finite element analysis.

机构信息

Department of Orthopaedic Surgery, College of Medicine, Chosun University, Gwangju, Republic of Korea.

出版信息

Knee Surg Sports Traumatol Arthrosc. 2011 May;19(5):842-9. doi: 10.1007/s00167-010-1383-y. Epub 2011 Jan 11.

Abstract

PURPOSE

The subtalar arthrodesis using screws has been performed to manage traumatic subtalar arthritis. Even though clinically there might not have been big difference between using single screw or double screws for subtalar arthrodesis, a double screw fixation is expected to bring a better initial stability in a mechanical view. This study aimed to assess the optimal configuration of double screw fixation for subtalar arthrodesis.

METHODS

From the CT-scanned images of an ankle of a Korean male (21 year old), polygon models of the talus and calcaneus were reconstructed. The polygon models were converted to tetrahedron finite elements. Young's modulus was assigned locally to each element based on the Hounsfield unit, and a Poisson's ratio of 0.4 was commonly. Four fixation configurations of double screw subtalar arthrodesis were modeled by combination of a same placement of a neck screw and one of four different placements of a dome screw, i.e., anterolateral (AL), anteromedial (AM), posterolateral (PL), and posteromedial (PM) placements. External and internal rotation torques of 4 N-m were applied when evaluating the stability of each fixation configuration.

RESULTS

Among the four fixation configurations, the fixation configuration of a neck screw plus a PM dome screw had the least translation of 0.9 and 0.8 mm for external and internal rotational torques of 4 N-m, respectively. The fixation configuration of a neck screw plus a PM dome screw showed the least rotation of 5.0° and 4.8° for external and internal rotational torques of 4 N-m, respectively. The divergence angle or the contact length did not solely match well to the better stability. However, the integration of both the divergence angle of 2 screws and the contact length between screw and bones were proportionally related to the better rotational stability.

CONCLUSION

A posteromedial dome screw combined with a neck screw can be the best surgical choice, which will bring out excellent union rate of the subtalar arthrodesis as well as the best mechanical stability.

摘要

目的

跗骨融合术使用螺钉已用于治疗创伤性距下关节炎。尽管在临床上使用单螺钉或双螺钉进行距下关节融合术可能没有太大区别,但从力学角度来看,双螺钉固定预计会带来更好的初始稳定性。本研究旨在评估双螺钉固定在距下关节融合术中的最佳配置。

方法

从一名韩国男性(21 岁)的踝关节 CT 扫描图像中,重建了距骨和跟骨的多边形模型。将多边形模型转换为四面体有限元。根据亨氏单位为每个元素局部分配杨氏模量,泊松比通常为 0.4。通过组合颈螺钉的相同放置和四个不同的穹顶螺钉放置之一,即前外侧(AL)、前内侧(AM)、后外侧(PL)和后内侧(PM)放置,对双螺钉距下关节融合术的四种固定配置进行建模。当评估每种固定配置的稳定性时,施加 4N-m 的外部和内部旋转扭矩。

结果

在四种固定配置中,颈螺钉加 PM 穹顶螺钉的固定配置在 4N-m 的外部和内部旋转扭矩下的平移量最小,分别为 0.9 和 0.8mm。颈螺钉加 PM 穹顶螺钉的固定配置在 4N-m 的外部和内部旋转扭矩下的旋转角度最小,分别为 5.0°和 4.8°。发散角或接触长度并不能单独与更好的稳定性匹配。然而,2 个螺钉的发散角和螺钉与骨骼之间的接触长度的综合情况与更好的旋转稳定性成正比。

结论

后内侧穹顶螺钉与颈螺钉结合可作为最佳手术选择,可获得距下关节融合术的优异愈合率和最佳机械稳定性。