Department of Ophthalmology, School of Dental Medicine, Tsurumi University, Yokohama, Japan.
Am J Ophthalmol. 2011 Mar;151(3):483-7.e1. doi: 10.1016/j.ajo.2010.08.045. Epub 2011 Jan 12.
To report the rate of recanalization and the efficacy of punctal occlusion surgery with a high heat-energy-releasing cautery device in patients with severe dry eye disease and recurrent punctal plug extrusion.
Prospective, interventional case series.
Seventy puncta from 44 eyes of 28 dry eye patients underwent punctal occlusion with thermal cautery. All patients had a history of recurrent punctal plug extrusion. A high heat-energy-releasing thermal cautery device (Optemp II V; Alcon Japan) was used for punctal occlusion surgery. Symptom scores, best-corrected visual acuity, fluorescein staining score, rose bengal staining score, tear film break-up time, and Schirmer test values were compared before and 3 months after the surgery. Rate of punctal recanalization also was examined.
Three months after surgical cauterization, symptom score decreased from 3.9 ± 0.23 to 0.56 ± 0.84 (P < .0001). Logarithm of the minimal angle of resolution best-corrected visual acuity improved from 0.11 ± 0.30 to 0.013 ± 0.22 (P = .003). Fluorescein staining score, rose bengal staining score, tear film break-up time, and the Schirmer test value also improved significantly after the surgery. Only 1 of 70 puncta recanalized after thermal cauterization (1.4%).
Punctal occlusion with the high heat-energy-releasing cautery device not only was associated with a low recanalization rate, but also with improvements in ocular surface wetness and better visual acuity.
报告在患有严重干眼疾病和反复泪点塞脱出的患者中,使用高热释放烧灼装置进行泪点阻塞的再通率和疗效。
前瞻性、干预性病例系列。
28 例干眼患者的 44 只眼中的 70 个泪点接受了热烧灼的泪点阻塞。所有患者均有反复泪点塞脱出史。使用高热释放热烧灼装置(Optemp II V;Alcon Japan)进行泪点阻塞手术。比较手术前后症状评分、最佳矫正视力、荧光素染色评分、孟加拉玫瑰红染色评分、泪膜破裂时间和泪液分泌试验值。还检查了泪点再通率。
手术烧灼 3 个月后,症状评分从 3.9 ± 0.23 降至 0.56 ± 0.84(P <.0001)。对数最小分辨角视力矫正视力从 0.11 ± 0.30 提高到 0.013 ± 0.22(P =.003)。荧光素染色评分、孟加拉玫瑰红染色评分、泪膜破裂时间和泪液分泌试验值在手术后也显著改善。只有 70 个泪点中的 1 个(1.4%)在热烧灼后再通。
高热释放烧灼装置的泪点阻塞不仅再通率低,而且还能改善眼表面湿润度和提高视力。