G.B. Bietti Eye Foundation-IRCCS, Rome, Italy.
Curr Opin Ophthalmol. 2011 Mar;22(2):115-23. doi: 10.1097/ICU.0b013e3283437222.
As spectral-domain optical coherence tomography (SD-OCT) progressively replaces time-domain OCT (TD-OCT) in the clinical and research setting, several commercially available instruments and new software upgrades for glaucoma diagnosis and progression analysis have been developed. Over the last year, several studies have been performed to assess the diagnostic performance of most of these instruments necessitating a review of their findings.
When compared with the measurements provided by TD-OCT, the conventional peripapillary circular scans by SD-OCT, which aim to measure the retinal nerve fiber layer (RNFL) thickness, show higher repeatability and similar diagnostic sensitivity. New software capabilities, such as the RNFL deviation map of Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA) or the macular Ganglion Cell Complex scan of RTVue (Optovue, Fremont, CA), provide complementary information that enhances our ability to discriminate between healthy and glaucomatous eyes.
SD-OCT-based instruments represent a technological advancement in the diagnosis of glaucoma. Improved repeatability will facilitate more reliable follow-up and progression analysis.
随着频域光学相干断层扫描(SD-OCT)在临床和研究领域逐渐取代时域 OCT(TD-OCT),已经开发出几种商业可用的仪器和用于青光眼诊断和进展分析的新软件升级。在过去的一年中,已经进行了几项研究来评估这些仪器中的大多数的诊断性能,因此需要对它们的研究结果进行综述。
与 TD-OCT 提供的测量值相比,SD-OCT 的传统的视盘环形扫描旨在测量视网膜神经纤维层(RNFL)厚度,具有更高的可重复性和相似的诊断敏感性。新的软件功能,如 Cirrus HD-OCT(Carl Zeiss Meditec,Dublin,CA)的 RNFL 偏差图或 RTVue(Optovue,Fremont,CA)的黄斑神经节细胞复合体扫描,提供了补充信息,增强了我们区分健康眼和青光眼眼的能力。
基于 SD-OCT 的仪器代表了青光眼诊断的技术进步。提高可重复性将有助于更可靠的随访和进展分析。