Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, People's Republic of China.
Invest Ophthalmol Vis Sci. 2010 Jan;51(1):217-22. doi: 10.1167/iovs.09-3468. Epub 2009 Aug 13.
To evaluate optical coherence tomography (OCT) retinal nerve fiber layer thickness (RNFLT) measurement for glaucoma progression analysis.
One hundred sixteen eyes of 64 patients with glaucoma who were observed within a period of 5 years were included. All eyes had at least four serial RNFL measurements obtained with the Stratus OCT (Carl Zeiss Meditec, Dublin, CA) and with the first and last measurements separated by at least 3 years. Visual field (VF) testing was performed on the same day as RNFL imaging. Serial average RNFLTs were evaluated with guided progression analysis (GPA). VF progression was assessed with trend analysis of the visual field index (VFI). Factors associated with the rate of change in RNFLT were examined with a linear mixed model.
A total of 1101 OCT scans and 1029 VFs were analyzed. Twenty-one and 22 eyes had progression according to RNFL and VF measurements, respectively, and 3 eyes had progression according to both measurements. The rate of change in VFI and RNFLT ranged between -0.5% and -7.2% per year (median loss, -3.0%/y) and between -1.2 and -15.4 microm per year (median loss, -3.3 microm/y), respectively. The sector at seven o'clock (right eye orientation) was the most frequent location that showed progression. A greater baseline RNFLT was associated with an increased rate of reduction of RNFLT (P = 0.034).
OCT GPA offers a new approach to augment glaucoma progression analysis. The rate of RNFLT thinning was variable among patients with glaucoma, with an increased rate of loss in patients with a higher baseline RNFLT.
评估光学相干断层扫描(OCT)视网膜神经纤维层厚度(RNFLT)测量在青光眼进展分析中的作用。
纳入了在 5 年内接受观察的 64 例青光眼患者的 116 只眼。所有眼均至少进行了 4 次连续的 Stratus OCT(德国卡尔蔡司公司,都柏林,加利福尼亚州)RNFL 测量,且第一次和最后一次测量之间至少间隔 3 年。同一天进行视野(VF)测试和 RNFL 成像。采用引导性进展分析(GPA)评估连续平均 RNFLT。采用视敏度指数(VFI)趋势分析评估 VF 进展。采用线性混合模型分析与 RNFLT 变化率相关的因素。
共分析了 1101 次 OCT 扫描和 1029 次 VF。根据 RNFL 和 VF 测量结果,分别有 21 只眼和 22 只眼发生进展,有 3 只眼根据两种测量结果都发生了进展。VFI 和 RNFLT 的变化率范围分别为每年-0.5%至-7.2%(中位数损失,-3.0%/y)和每年-1.2 至-15.4 微米(中位数损失,-3.3 微米/y)。七点钟方向(右眼方位)是最常发生进展的部位。基线 RNFLT 越高,RNFLT 减少率越高(P = 0.034)。
OCT GPA 为青光眼进展分析提供了一种新方法。青光眼患者的 RNFLT 变薄率存在差异,基线 RNFLT 较高的患者损失速度更快。